ERROR MESSAGE
Error messages appear on the display
.
Memory Roll
1. From the [ENCODER]
menu, select [Travel
calibr]. Press ENTER to
confirm
2. Select [Confirm?
(Yes)] and press
ENTER to confirm.
3. M1's gate leaf will
perform a new closing until
it completely stops...
4. ...then, M2's gate
leaf will perform the
same closing...
5. ... and then M2's gate
leaf will perform a full
opening...
6. ... after which, M1's
gate leaf will also
perform a full opening.
7. Once the procedure is
completed, the display will
read [Travel calibr OK] for
a few seconds.
Travel calibration
⚠ Before calibrating the gate run, check that the maneuvering area is free from any obstruction and that there are both opening and
closing mechanical stops.
⚠ The mechanical end-stops are obligatory.
Important! During the calibration, all safety devices will be disabled except for the PARTIAL STOP one.
Memory Roll Card
For memorizing user and system configuration data, then using them on another control board.
After memorizing the data, it is best to remove the Memory Roll card while the control board is in operation.
[Encoder - ERROR], [Error!]
Broken encoder or wrong connection.
[Safety Test - ERROR]
Safety devices malfunctioning.
[End Stop - ERROR]
Malfunctioning endstop contacts
[Cycle time - ERROR]
Insufficient working time
[Safety - STOP], [C1], [C3], [C4], [C7] or [C8]
Malfunctioning safety devices or wrong connection
www.metalines.com