CAME ZM3E Installation Manual - page 14
p.
1
4
14
- M
an
u
al c
od
e:
F
A
0
0
3
8
5
-E
N
FA
0
0
3
8
5
-E
N
v.
1
1
0
2
/2
0
1
6 © C
A
M
E c
an
ce
lli auto
m
ati
ci S
.p.
A
. - T
h
e c
onte
nts of th
is m
an
u
al m
ay b
e c
h
an
g
ed at a
ny ti
m
e w
ith
ou
t p
rio
r n
oti
ce
.
Time settings menu
[SET TIMES]
[ACT]
[0 s]
⇨
[300 s]
The fi rst automatic-closing wait starts when the opening endstop point is reached and can be set to between 0 and 300 s. The automatic
closing does not turn on if any of the safety devices trigger when an obstruction is detected, after a total stop or during a power outage.
[Pedestrian ACT]
[0 s]
⇨
[300 s]
Waiting time of M2's second leaf in the open position. Once this time elapses, a closing maneuver is automatically performed. The waiting
time can be set to between 0 and 300 seconds.
[Cycle time]
[10 s]
⇨
[150 s]
Gearmotor working time during opening and closing. The working time can be set to between 10 and 150 seconds.
[Opening Delay M1]
[0 s]
⇨
[10 s]
M1 opening delay with respect to M2 after each opening command. The waiting time can be set to between 0 and 10 seconds.
[Closing Delay M2]
[0 s]
⇨
[60 s]
M2's closing delay with respect to M1's closing after each closing command. The waiting time can be set to between 0 and 60 seconds.
[Prefl ash time]
[1 s]
⇨
[60 s]
After and opening or closing command, the flashing light connected to W-E, flashes from between 1 and 60 seconds before starting the
maneuver.
[Lock time]
[1 s]
⇨
[5 s]
Intervention time for the electrolock to release after each opening command. The intervention time can be adjusted to between one second and fi ve secon-
ds.
[Ram jolt time]
[1 s]
⇨
[10 s]
The closing and opening jolt thrust-time of the geartmotors after each command. The thrust time can be set to between
one and three
seconds.
[Partial open]
[5 s]
⇨
[60 s]
M2's opening time. The time can be adjusted to between fi ve seconds and 60 seconds.
[Slow down time]
[OFF]
⇨
[30 s]
Leaf slow-down time before each end stop. The time can be set to between zero and 30 s.
This function appears only if the following slow downs are set, [Op LS-Cl Sl Dn] or [Time Lmt Swtch] from the [Confi g] function.
[M2 Opn Slw Dwn]
[1%]
⇨
[60%]
Adjusting M2's slow-down starting point before the opening endstop.
The slow-down starting point is calculated as a percentage (from 1% to 60% of the complete gate-leaf run).
This function only appears if the [Enc. Slwdwn.] function in the [ENCODER] menu.
[M2 Cls Slw Dwn]
[1%]
⇨
[60%]
Adjusting M2's slow-down starting point before the closing endstop.
The slow-down starting point is calculated as a percentage (from 1% to 60% of the complete gate-leaf run).
This function only appears if the [Enc. Slwdwn.] function in the [ENCODER] menu.
[M1 Close Accel]
[1%]
⇨
[15%]
M1's approach starting point is calculated as a percentage (from 1% to 15% of the complete gate-leaf run) before the closing endstop.
[M2 Close Accel]
[1%]
⇨
[15%]
M2's resting starting point is calculated as a percentage (from 1% to 15% of the complete gate-leaf run) before the closing endstop.
[M1 Open Accel]
[1%]
⇨
[15%]
M1's approach starting point is calculated as a percentage (from 1% to 15% of the complete gate-leaf run) before the closing endstop.
[M2 Open Accel]
[1%]
⇨
[15%]
M2's approach starting point is calculated as a percentage (from 1% to 15% of the complete gate-leaf run) before the opening endstop.
[Travel calibr]
Automatic calibration of the gate-leaf run (see the TRAVEL CALIBRATION paragraph).