Campbell CCFC Instruction Manual - page 19
CCFC Field Camera
9
7.1 Power
I/O
Connection
Connection to the Power I/O connector is necessary for camera operation, as it
is the only means to supply power to the camera. The connector that connects
to the Power I/O connector provides a weather-tight connection and has an
IP68 environmental rating when properly connected. Even when the camera is
not in use, the power cable must be left connected, if the camera is to be left
installed.
When connecting the cable to the camera, the notch positions must always line
up.
7.2 Setup Button/Status LED
The Setup Button is located behind a protective cap on the camera. The Setup
Button also contains an integrated Status LED for user feedback.
7.2.1 Status
LED
The Status LED located in the center of the Setup Button provides some useful
diagnostic information about the camera. Table 7-1 describes the Status LED
behavior. This assumes the power supply is between 9 - 30 Vdc.
Table 7-1 Setup Button Status LED
LED CCFC
State
Other
Continuously Off
No power or the camera is in one of
the following low powered modes:
x Partially On
x Deep Sleep
x Off Mode
Pressing the Setup Button forces the camera to exit
any of the low powered modes and remain Fully
On for a period of 5 min with the LED rapidly
flashing.
Slow Flash
1 sec on, 3 sec off
Normal Operation in Fully On
power mode.
Rapid Flash
Exit from low power state. The
camera is being kept on by:
x Timeout (from the Setup
Button press)
x Network Communications
x Asserted External Trigger
x Photo or video acquisition
Continuously On
The camera is booting up - this
process takes approximately 90 sec.
The camera will be required to boot up whenever:
x Power is first applied to it.
x The camera is exiting the Off Power mode
to perform an operation.