Destination
Drop down to select a configured FTP profile. Use the Edit button
to setup FTP profiles via the FTP Settings modal (see Section
12.8.3.1 FTP).
Send via PakBus
Toggle
Enabling initates sending videos via the PakBus modal (see Section
12.8.3.3 PakBus).
PakBus Port
PakBus Port number is displayed. Use the Edit button to edit the
PackBus Settings via the PakBus modal (see Section 12.8.3.3
PakBus).
12.4.2 External Trigger
This section applies to use with a datalogger or other applicable
trigger source.
External Trigger is used to configure the camera to capture photos or video
using an external signal that is applied to the External Trigger input line. In
order to activate the External Trigger capture, refer to the wiring table (Table
8-1 Power & I/O Cable Connections) for information on which wires need to
be connected.
Figure 12-10 External Trigger
External Trigger can be configured to Active High or Active Low. When set to
Active High, 0 volts is the Inactive state and a positive voltage is the Active
state.
The CCFC is shipped from the factory with a pull down resistor connected to
the External Trigger and the External Trigger is set to Active High. With this
default setting, when no signal is applied to the input, the External Trigger is
inactive. A positive voltage is required to change to the active state.
The External Trigger can be configured for an Active High signal or an Active
Low signal. The capture is triggered by the transition from the inactive state to
the active state. The minimum required pulse period is 10 miliseconds (msec).
Preferably, pulses should be short in duration (milliseconds). No les than 1 sec
between captures is recommended with no more than 5 in a 10 second period.
Note