Campbell CCFC Instruction Manual - page 98
CCFC Field Camera
88
When the Force Retrieval box is selected, a file that matches the file pattern
will be retrieved regardless of the file’s timestamp or whether the file has
already been retrieved. When the Record If Skipped box is selected, the names
and dates of any files that are not retrieved because of the Max Files parameter
will be recorded and they will not be retrieved later. If this box is not selected,
the skipped files can be retrieved in a later attempt.
19.2 Using LoggerNet File Control
Photos or video that are in the datalogger memory can be viewed or collected
on demand by using File Control that is available from the Connection Screen
menu. The use of File Control requires a communications connection to the
datalogger. Using the File Control can also be useful for debugging purposes.
Figure 19-2 Loggernet Connection Screen
In dataloggers such as the CR1000, the Device Map can include the CPU,
USR, and the CRD (compact flash module). The devices show up in the left
hand side of the File Control panel. To view files of a certain device, simply
click on the desired device listed in the panel (Figure 19-3 USR Drive View in
File Control). Use the Retrieve button to download the photo from the
datalogger.
File Control