Canon ImageCLASS MF4690 Service Manual - page 143
Chapter 14
14-3
#MENU
No.
Initial setting
Range of
setting
Function
01: - 04:
not used
05:
0
ON/OFF
NL equalizer setting
06:
0
0: DIAL
1: SERVICEMAN [1]
2: SERVICEMAN [2]
3: OFF
line monitor setting
07:
10
0-15
transmission level setting
08:
0
0: 3429
1: 3200
2: 3000
3: 2800
4: 2743
5: 2400
V.34 baud rate
09:
0
0: 33.6kbs
1: 31.2kbs
2: 28.8kbs
3: 26.4kbs
4: 24.0kbs
5: 21.6kbs
6: 19.2kbs
7: 16.8kbs
8: 14.4kbs
9: 12.0kbs
10: 9.6kbs
11: 7.2kbs
12: 4.8kbs
13: 2.4kbs
V.34 transmission speed
10:
1
0: 50Hz
1: 25Hz
2: 17Hz
3: 20Hz
pseudo CI signal frequency setting
11: - 20:
not used
#NUMERIC
No.
Initial setting
Range of setting
Function
001:
not used
002:
10 (10%)
(1-99)
RTN signal transmission condition (1) setting
003:
15 (15lines)
(2-8)
RTN signal transmission condition (2) setting
004:
12 (12times)
(1-99)
RTN signal transmission condition (3) setting
005:
4 (4sec)
(1-60)
NCC pause time (pre-ID code) setting
006:
4 (4sec)
(1-60)
NCC pause time (post-ID code) setting
007: - 009:
not used
010:
5500 (55sec)
(0-9999)
line connection identification time length
011:
3500 (35sec)
(0-9999)
T.30 T1 timer (for reception)
012:
not used
013:
1300 (13sec)
(500-3000)
T30 EOL timer
014:
not used
015:
120 (1200ms)
(0-999)
hooking detection time setting
016:
4 (4sec)
(0-9)
fax/tel switch-over function: between line acquisition and pseudo
RBTtransmission
017:
100 (1000ms)
(0-999)
pseudo RBT signal pattern: ON time setting
018:
0 (0ms)
(0-999)
pseudo RBT signal pattern: OFF time (short) setting
019:
200 (2000ms)
(0-999)
pseudo RBT signal pattern: OFF time (long) setting
020:
100 (1000ms)
(0-999)
pseudo CI signal pattern: ON time setting
021:
0 (0ms)
(0-999)
pseudo CI signal pattern: OFF time (short) setting
022:
200 (2000ms)
(0-999)
pseudo CI signal pattern: OFF time (long) setting
023:
4
(0-7)
fax/tel switch-over pseudo RBT transmission level
024:
20 (-20dBm)
(0-20)
fax/tel switch-over pseudo RBT transmission level
025:
60 (60sec)
(0-999)
Answering machine connection function signal detection time
026:
not used
027:
0
(0-20)
V21 low-speed flag preamble detection time length