Canon ImageCLASS MF4690 Service Manual - page 147
Chapter 14
14-7
F-14-2
Do not change service data identified as "not used"; they are set as initial settings.
14.3.2 SSSW-SW01:
14.3.2.1 List of Functions
0016-2002
T-14-1
14.3.2.2 Detailed Discussions of Bit 0
0016-2003
Selects whether or not service error codes are output.
When output is selected, service error codes is report.
14.3.3 SSSW-SW03
14.3.3.1 List of Functions
0016-2004
T-14-2
14.3.3.2 Detailed Discussions of Bit 7
0016-2005
Use it to enable/disable transmission of a 1080-Hz tonal signal before transmission of the CED signal.
Select 'transmit' if errors occur frequently because of an echo when reception is from overseas.
Memo:
Any of the following error code may be indicated because of an echo at time of reception
##0005, ##0101, ##0106, ##0107, ##0114, ##0200, ##0201, ##0790
Bit
Function
1
0
0
service error code
output
not output
1
not used
-
-
2
not used
-
-
3
not used
-
-
4
not used
-
-
5
not used
-
-
6
not used
-
-
7
not used
-
-
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
not used
-
-
3
not used
-
-
4
not used
-
-
5
not used
-
-
6
not used
-
-
7
tonal signal before CED signal transmission
transmit
do not transmit
001
#SSSW
0
0
0
0
0
0
0
0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0