  • Page 1

    Owners manual installation operation specifications features maintenance warranty 65-00087-004 rev 02_04 fa sp-eng om - 02_04.

  • Page 2

    2 inspection & installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 3

    3 1. Remove protective packaging. 2. Remove unit from shipping carton. 3. Remove all protective materials. 4. Check for shipping damage and loose or broken parts. 5. Read owners manual thoroughly prior to installation. 6. Install batteries in remote. 7. Determine placement location for the unit (see...

  • Page 4

    4 electrical: • 100 volt 50/60hz, 110 volt 60 hz, 220/240 volt 50/60 hz depending on model • 90 watts power consumption • 24 to 30 kv, 20-30 khz ion generation pulsator • fixed 6 kv dc needle ion generator mechanical: • 400 cfm fan size: • dimensions: 12” high x 9” wide x 12” deep • weight: 16 pound...

  • Page 5

    5 • five speed fan • adjustable purifier control • lcd display • sanitizer function w/ adjustable digital timer • intelliair™ maintenance reminders infrared window back of unit / rear access lcd display main power switch fuse power cord receptacle controls removable grill unit features • intelliair™...

  • Page 6

    6 settings and adjustments fresh air by ecoquest can be turned on or off and adjusted using either the included remote or the control panel on the front of the unit. With the exception of the reminder reset button, both the remote and the control panel buttons have the same functions. Power on/off f...

  • Page 7

    7 perform maintenance (approx. Every 30 days) • vacuum lint screen • clean purifier plate • clean the catalytic screen • vacuum front and rear grill openings install plate the purifier plate is missing or installed incorrectly • install or re-install purifier plate correctly replace plate the purifi...

  • Page 8

    8 general maintenance periodic maintenance is required to insure that your fresh air by ecoquest operates properly. The unit will display a perform maintenance reminder when it is time to perform regular maintenance. If you are operating your unit in a severely polluted environment, cleaning of the ...

  • Page 9

    9 optional ecohelp filter changing the uv lamp the uv lamp should be changed when replace lamp appears on the display. To change the lamp follow the instructions on pages 10 - 13. Changing the fuse: the fuse may be accessed by unplugging the cord from the back of the unit and gently pulling the fuse...

  • Page 10

    5 4 3 1 2 10 removing the lint screen 1. Unplug unit. 2. Remove the two (2) back cover screws. 3. Remove back cover. 4. Remove two (2) screws securing the top of the lint screen holder. Warning: do not operate fresh air by ecoquest without the lint screen and back cover properly installed. To remove...

  • Page 11

    11 10 9 8 7 11 7. To remove the catalytic screen, grasp the frame and gently pull screen out of unit. 9. Loosen two (2) screws holding the plate cage. Slide the cage forward, lift and remove. 10. Rotate starter and lift to remove. 11. Rotate uv bulb 1/4 turn, lift out of holders, and remove from uni...

  • Page 12

    6 5 4 3 2 1 12 to install: lint screen or ecohelp filter follow steps 7 - 11 purifier plate follow steps 6 - 11 installing the uv lamp 1. Insert uv bulb into holder then rotate to lock into place. 2. Replace starter and turn to lock. 3. Replace cage by lowering and sliding back into place. Tighten t...

  • Page 13

    11 10 9 8 7 13 11. Reinstall the power cord. 8. Be sure the lint screen depresses the metal tab. 7. Replace lint screen and the top of the lint screen holder at the same time. 10. Replace two (2) back cover screws. 9. Replace two (2) lint screen top holder screws. Installing the lint screen warning:...

  • Page 14

    14 troubleshooting indicators of operation when the unit is on the lcd display will show the fan setting, purifier setting, and square footage. If the unit is in sanitizer mode, it will display sanitize and the hours and minutes remaining. Troubleshooting - what to look for first. 1. I have plugged ...

  • Page 15

    4. The uv lamp is not functioning / i’m getting a “replace lamp” message. • check lamp for proper installation. • replace uv lamp. Please note: if unit has been recently transported check lamp for proper installation, remove lamp and reinstall. 5. What are the most typical application problems? • sy...

  • Page 16

    Warranty information this product is of solid state construction and is warrantied by ecoquest international 310 t. Elmer cox drive greeneville, tn 37743 to the original purchaser, depending on model, to be free from defect in materials and workmanship for a limited time. Length of warranty will var...