Garland XE24 Installation, Operating & Service Instructions - Programming Continued
Part # 4517125 (09/03)
Page 25
8. Press to return to “PROGRAMMING MODE
SERVICE MODE”
9. Press again to exit.
To Perform Limit Switch Test:
1. Press and hold for three, (3) seconds. “ENTER
CODE” will be displayed.
2. Using the Gap Setting buttons,
enter the code, (1251). “ENTER CODE **** ” will
be displayed.
3. Press
to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS”
will be displayed.
4. Press
three, (3) times. “PROGRAMMING
MODE SERVICE MODE” is displayed.
5. Press
two, (2), times. “PLATEN” (along with
the position of each switch), will be displayed.
6. Use and to move the platen up and down.
Check for correct switch operation:
Correct Switch Operation:
Platen Up - U (Closed) L (Open)
Platen Down - U (Open) L (Closed)
7. Press to return to “PROGRAMMING MODE
SERVICE MODE”
8. Press again to exit.
PROGRAMMING continued
Gap Button
To Change Gap Setting:
1. Press and hold for three, (3) seconds. “ENTER
CODE” will be displayed.
2. Using the Gap Setting buttons,
enter the code, (1251). “ENTER CODE **** ” will
be displayed.
3. Press
to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS”
will be displayed.
4. Press
. “GAP LEVEL 1 X.XXX” will be
displayed.
5. Press until the desired Gap Level is displayed.
6. Use
and
to adjust the Gap Level to the
desired value.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE
MENU ITEMS”
9. Press again to exit.