Garmin GMX 200 Installation Manual - page 59
4.
Using the menu (displayed by pressing the MENU/ENT key), press the OPERATE line select key to
change the mode from ‘TIS Operating’/’TIS Unavailable’ to ‘TIS Standby’. Verify that the TIS
mode changes accordingly.
5.5.7
81B
TAWS System Interface Test
5.5.7.1
105B
L3 Landmark TAWS and Honeywell KGP 560/860 TAWS Checkout
If an L3 Communications Landmark TAWS 8000 or Honeywell (Bendix/King) KGP 560/860 TAWS /
KMH 820 IHAS system has been connected to the GMX 200 I/O, the interface should be verified as
described in this section.
1.
Verify that the amber TAWS flag is not displayed.
2.
Select the Terrain (TER) function on the GMX 200.
3.
From the TAWS control panel, execute a self-test. Verify that the GMX 200 displays the TAWS-
generated test pattern and the TAWS annunciators (at the top of the terrain page).
4.
After the self-test has completed, verify that the GMX 200 range up and range down keys change the
corresponding range being presented by the TAWS.
GMX 200 Installation Manual
Page 5-25
190-00607-04