Summary of K 5.86 M

  • Page 1

    K 5.80 m 5.960-830 (2004330-04-03) caution! Do not use the unit without first having read the operating instructions..

  • Page 2

    2 short instructions 1 drawing bar transport unit over even surfaces 2 hand gun storage clip 3 master switch switch on unit – i switch off unit – 0 4 high pressure outlet connect high-pressure hose 5 water connection connect supply hose 6 spray lance regulate pressure 7 handgun switch on – press saf...

  • Page 3

    3 assembly.

  • Page 4

    4 safety notes before first use of the unit read these operating instructions and act in accordance with them. Keep these operating instructions in a safe place for later use or for a subsequent owner. Use of the unit as authorized use this unit exclusively for non-industrial purposes – for cleaning...

  • Page 5

    Before first use connection requirements see rating plate or technical data for connected values. Electrical connection the voltage shown on the rating plate must match the supply voltage. The current source must be properly earthed. Only use splash-protected extension cable with a sufficient conduc...

  • Page 6

    6 preparation l insert power plug. L turn master switch to “i”. Switching on l press safety button on the handgun and pull the lever. Switching off l release the lever. During breaks in work and when leaving the unit secure it against inadvertent switching on by pressing the safety button. Regulate ...

  • Page 7

    7 adding the cleaning agent l draw the deregent suction hose out of the hou- sing to the required length. L meter out the detergent. – medium quantity: centre-position – large quantity: “+” position – small quantity: “–” position. L hang the deregent suction hose in the detergent container. L twist ...

  • Page 8

    8 l pull the lever on the handgun until the unit is without pressure. L press in the safety button to protect the unit against inadvertent switching on. L wind the high-pressure hose. Caution! Frost can destroy an incompletely emptied unit. In the winter keep the unit in a frost-free room. L place t...

  • Page 9

    9 help with faults fault cause remedy unit does not run power supply interrupted draw out power plug! Check power cord, power plug, extension cable and cable connections for damage unit does not come up to pressure spray lance set to “–” set spray lance to “+” in suction operation – unit not vented ...

  • Page 10

    10 technical data power supply voltage (at 1~50 hz) 230-240 v connected load 2,1 kw supply fuses (time-lag) 10 a safety class 1,ip x5 water connection supply temperature (max.) 40 °c supply volume (min.) 10 l/min supply pressure (max.) (6 bar) 0,6 mpa performance data operating pressure (125 bar) 12...

  • Page 11

    11 special accessories special accessories expand the scope of use of your machine. You can obtain further information from your kärcher dealer. See page 12 for illustrations. 1 rotary nozzle 2 spray guard for rotary nozzle 3 pipe-cleaning set 4 rotating wash brush 5 wash brush 6 wet blasting set 7 ...

  • Page 12

    Special accessories.