Lantech IES-2208CA User manual - page 128
121
switch(config)#no security telnet
no security snmp
G
Disable IP security of
SNMP server
switch>enable
switch#configure
switch(config)#no security snmp
Port Security Commands Set
Netstar Commands
Level Description
Example
mac-address-table static
hwaddr
[HW-Addr]
I
Configure MAC
address entry of
interface (static).
switch>enable
switch#configure
switch(config)#interface
fastEthernet 2
switch(config-if)#mac-address-
table static hwaddr
000012345678
show mac-address-table
static
P
Show MAC address
table (static)
switch>enable
switch#show mac-address-table
static
no mac-address-table
static hwaddr
[HW-Addr]
I
Remove an entry of
MAC address table of
interface (static)
switch>enable
switch#configure
switch(config)#interface
fastEthernet 2
switch(config-if)#no mac-address-
table static hwaddr
000012345678
MAC Blacklist Commands Set
Netstar Commands
Level Description
Example
mac-address-table filter
hwaddr
[HW-Addr]
G
Configure MAC
address entry of
interface (filter)
switch>enable
switch#configure
switch(config)#mac-address-table
filter hwaddr 000012348678
show mac-address-table
filter
P
Show MAC address
table (filter).
switch>enable
switch#show mac-address-table
filter
no mac-address-table
G
Remove an entry of
switch>enable