NEC ElectraElite IPK Installation And Maintenance Manual - page 14
SPE Hardware, Installation, and Maintenance Manual
1 - 1
___________________________________________________________________________________
___________________________________________________________________________________
Chapter 1
Electra Elite IPK SPE(M)-U( ) ETU
S
ECTION
1
D
ESCRIPTION
The Single Point of Entry [SPE(M)-U( ) ETU] provides a single access point (remote
or direct) for configuring the system and/or individual cards. The SPE(M)-U( ) ETU
provides the same functionally as a MIF(M)-U( ) ETU with the Activation key
[KMM( )-U] installed, plus a modem unit. An Ethernet port is also provided to allow
programming over a network using TCP/IP.
The SPE(M)-U( ) ETU has six physical COM ports. Two go through the backplane to
COM1 (for PC Programming) and COM2 (for SMDR) on the side of the KSU just like
a MIF(M)-U( ) ETU. The other four COM ports (COM-A, COM-B, COM-C, and
COM-D) are accessible along the front of the card. These COM ports are used for
interfacing to other programmable cards such as a VMS, etc.
The SPE(M)-U( ) ETU provides three methods of communications to the Electra Elite
IPK or Electra Elite 48/192 systems.
K
Serial — Using COM 1 on the KSU
K
Modem — v.34 @ 33.6 Baud
K
Ethernet — 10/100Mbps LAN/WAN Connection
The following table provides a comparison between the MIFM and the SPE ETUs.
Table 1-1 Comparison of ETUs
Feature
MIFM
SPE
Hardware Components
MIF(M)-U( ) ETU
KMM PAL chip
Socket Modem Unit
SPE( )-U( ) ETU
SAT Programming via serial
Yes
Yes
SAT Programming via Modem
Yes (Optional)
Yes (Standard)
Maximum Modem Speed
38.4 Kbps
38.4 Kbps
SAT Programming via Ethernet
(Intra/Internet)
Yes (Optional) with Elite
LAN PC Programming
Device
Yes