Pacific Energy granville Installation And Operating Instructions Manual - Glowing Embers
13
040805-24
GRNA
# 5055.651
Glowing Embers
Note: Use only glowing embers supplied with the
appliance. Use of any other materials or incorrectly
placed embers may cause an incorrect flame pattern,
sooting and/or delayed ignition.
Place 10 to 12 pieces randomly on the front burner area
as shown in figure #22. This will produce the best
results.
Louver Installation
Unpack and inspect all parts. A flathead or a #2
Robertson screwdriver is required to install the lou-
vers.
1) Fasten top louver to the top casing with the screws
provided (see Fig. #23).
2) Fasten bottom louver to the hinge brackets at the
bottom of the appliance (see Fig. #21).
Fig. # 22
Embers
Fig. # 23
Fig. # 21
Glass Frame Installation
The glass frame assembly is designed for easy installa-
tion and removal with positioning tabs on top of the
firebox and quick release latches located under the
firebox.
Installation:
1) Grasp the sides of the glass frame assembly and
hook over the frame tabs. Ensure that the tabs on the
top of the unit engage the corresponding slots in the
glass frame.
2) Swing the bottom into position and latch in place
with the over-center latches (Fig. #24).
Removal:
1) Fold down the bottom louver, if installed, to access
the over-center latches. Disengage the latches by
pulling each lever down and forward (Fig. #24).
2) Grasp the sides of the frame and swing the bottom
out to clear. Lift up and then forward to disengage
from top (Fig. #24).
Fig. # 24
Glass Frame Tabs
Glass Frame Latch
f i r e - p a r t s . c o m