    Warning: if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. -- do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • what to do if you smell...

  • Page 2: Contents

    2 040805-24 grna # 5055.651 contents caution .......................................................................................3 safety .........................................................................................3 maintenance ...........................................................

  • Page 3: Caution

    3 040805-24 grna # 5055.651 caution for your safety - do not install or operate your pacific energy granville direct vent gas insert without first reading and understanding this manual. Any installation or opera- tional deviation from the following instructions voids the pacific energy warranty and ...

  • Page 4: Installation

    4 040805-24 grna # 5055.651 installation the granville direct vent gas insert installation and venting must conform to the current can/cga-b149.1 installation code (in canada) or the national fuel gas code, ansi z223.1 -1988 (in the usa), and approved per local codes. Only qualified (licensed or tra...

  • Page 5: Clearances

    5 040805-24 grna # 5055.651 clearances the minimum clearances from the appliance to combustible surfaces are shown on fig. #4 and #5. Adequate clearances around air openings and air supplies are required. Fig. # 4 fig. # 5 minimum clearances to combustibles: adjacent sidewall: .........................

  • Page 6: Venting

    6 040805-24 grna # 5055.651 venting caution: only flex liner kit (mind.Fl25) or an approved gas vent flue liner and a vent terminal (mind.Vtterm) is approved for use with this appliance. Also approved for use is simpson dura-vent gs termination kits, both standard vertical termination cap (#980) and...

  • Page 7: Rocker Switch

    7 040805-24 grna # 5055.651 make sure the marked inlet pipe is attached to the inlet side (marked "i"), and the unmarked pipe is attached to the outlet side (marked "e") of the connector plate. 7) seal and secure inlet pipe with sealant and screws pro- vided. 8) slip the 3 1/2" pipe clamp loosely ov...

  • Page 8: Gas Supply

    8 040805-24 grna # 5055.651 gas supply caution: the gas line should be installed by a qualified service person in accordance with all building codes. Consult local and/or national building codes before pro- ceeding. The gas valve inlet accepts a 3/8" n.P.T. Fitting. Correct gas line diameter must be...

  • Page 9: Burner Removal

    9 040805-24 grna # 5055.651 fig # 14 fig # 12 burner attachment screws burner removal caution: turn off gas and electrical power supply and allow ample time for unit to cool before proceed- ing. 1) fold down the bottom louver, if installed, to access the over-center latch. Disengage the latches by p...

  • Page 10: Log Set

    10 040805-24 grna # 5055.651 fig. # 15c step 4 top left log placement (log #4) step 1 rear log placement (log #1) step 3 lower right log placement (log #3) step 2 lower left log placement (log #2) fig. # 15a andirons log tabs log set the ceramic logs are durable and long lasting when installed prope...

  • Page 11

    11 040805-24 grna # 5055.651 2 7 5 3 6 4 fig. # 15f 1 step 7 rear right log placement (log #7) step 6 rear left log placement (log #6) step 5 top right log placement (log #5) fig. # 15e fig. # 15d f i r e - p a r t s . C o m.

  • Page 12: Surround Assembly

    12 040805-24 grna # 5055.651 surround assembly 1) lay parts a, b, and c face down on a flat, non-marking surface. (fig. #16) fasten together with spring clips through holes at points "d". (fig. #19) 2) lift the surround assembly to the upright position and make sure the front face is even at the joi...

  • Page 13: Glowing Embers

    13 040805-24 grna # 5055.651 glowing embers note: use only glowing embers supplied with the appliance. Use of any other materials or incorrectly placed embers may cause an incorrect flame pattern, sooting and/or delayed ignition. Place 10 to 12 pieces randomly on the front burner area as shown in fi...

  • Page 14: Lighting Instructions

    14 040805-24 grna # 5055.651 for your safety read before lighting lighting instructions to turn off gas to appliance 1. Set wall thermostat to lowest setting, if applica- ble. 2. Turn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn...

  • Page 15: First Fire

    15 040805-24 grna # 5055.651 first fire when lit for the first time, the appliance will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. Sm...

  • Page 16: Optional Blower

    16 040805-24 grna # 5055.651 optional blower installation: the burner assembly must be removed for blower kit installation. Follow "burner removal" section for removal. Unpack and inspect blower kit. 1) position the blower assembly over the two studs located at the rear of the appliance so that the ...

  • Page 17: Optional Radiant Overlay

    17 040805-24 grna # 5055.651 optional radiant overlay the optional radiant overlay may be installed at any time. Unpack and inspect all parts. Install overlay as follows: 1) remove the glass frame assembly from the appliance if installed. Place face up on a flat, stable surface to avoid damage. 2) r...

  • Page 18: Replacement Parts

    18 040805-24 grna # 5055.651 replacement parts see fig. # 32 (when ordering, include part number with description) item description part no. Item description part no. 1 ...... Vent connector plate ................................................... Mind.1823 2 ...... Gasket, vent connector ............

  • Page 19

    19 040805-24 grna # 5055.651 fig. # 32 2 5 3 4 1 3 6 7 8 9 3 15 17 16 14 13 11 10 12 f i r e - p a r t s . C o m.

  • Page 20: Burner Replacement Parts

    20 040805-24 grna # 5055.651 a a e e ff n n t t o o iill oo pp ff ii h h o o l loo tptp thth tptp thth 23 24 18 21 22 20 17 15 14 16 19 25 26 1 2 9 12 10 7 8 6 11 3 4 5 13 burner replacement parts see fig. # 33 (when ordering, include part number with description) item description part no. Item desc...

  • Page 21: Appendix A

    21 040805-24 grna # 5055.651 appendix a 250901 mind-vtterm 5055.658 please refer to the installation instructions provided with the appliance for proper installation. This box contains: direct vent terminal kit mind.Vtterm 1 .......Vent terminal 4 .......#10 x 5/8" teks screws 6 .......#10 x 1 1/2" ...

  • Page 22

    22 040805-24 grna # 5055.651 printed in canada 250901 mind-fla 5055.659 vent terminal flashing installation guide mind.Flash this kit contains: 1 ..... Vent terminal flashing 4 ..... #8 x 1" sheet metal screws installation: 1. Attach the vent terminal to the flashing using the 4 screws provided. 2. ...

  • Page 23: Rating Label

    23 040805-24 grna # 5055.651 rating label propane conversion rating label f i r e - p a r t s . C o m.