Pacific Energy granville Installation And Operating Instructions Manual - Caution
3
040805-24
GRNA
# 5055.651
Caution
FOR YOUR SAFETY - Do not install or operate your Pacific
Energy Granville Direct Vent Gas Insert without first reading
and understanding this manual. Any installation or opera-
tional deviation from the following instructions voids the
Pacific Energy Warranty and may prove hazardous.
This appliance and its individual shutoff valve must be dis-
connected from gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig.
(3.5 kPa)
This appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.5 kPa)
Note: When lit for the first time, the appliance will emit a
slight odour for a couple of hours. This is due to the curing of
paints, sealants and lubricants used in the manufacturing
process. This condition is temporary. Open doors and
windows to ventilate area. Smoke and fumes caused by the
curing process may cause discomfort to some individuals.
Safety
Due to high temperatures, this gas appliance should be
located out of traffic and away from furniture and
draperies.
Children and adults should be alerted to the hazards of
high surface temperature and should stay away to avoid
burns or clothing ignition.
Young children should be carefully supervised when they
are in the same room as the appliance.
Clothing or other flammable material should not be placed
on or near the appliance.
Any grill, panel or door removed for servicing the unit
must be replaced prior to operating. Failure to do so may
create a hazardous condition.
Installation and repair should be done by a qualified
service person. The appliance should be inspected before
use and at least annually by a professional service person.
More frequent cleaning may be required due to excessive
lint from carpeting, bedding material, etc. It is imperative
that control compartments, burners and circulating air
passageways of the appliance be kept clean.
It is Pacific Energy’s policy that no responsibility is
assumed by the Company or by any of its employees or
representatives for any damages caused by an inoperable,
inadequate, or unsafe condition which is the result, either
directly or indirectly, of any improper operation or
installation procedures.
Maintenance
Caution: Turn off gas and electrical power supply and allow
ample time for unit to cool before servicing appliance. It is
recommended that this appliance and venting should be
inspected at least once a year by a qualified service person.
Do not use this heater if any part has been under water.
Immediately call a qualified service technician to inspect the
heater and to replace any part of the control system and any gas
control which has been under water.
Annual Inspection:
a) Clean louvers and air passage ways of excessive lint
buildup from carpeting, bedding material, etc. The flow of
ventilation air must not be obstructed.
b) Inspect logs and burner assembly for lint and soot buildup.
If excessive buildup of soot is present, have a qualified service
person inspect and adjust unit for proper combustion. Clean
logs and burner with a vacuum cleaner, paying close attention
to burner ports.
c) Check the pilot system for proper flame size and opera-
tion. Clean pilot free of lint or soot. (See Fig. #1)
d) Check that the vent pipe and vent terminal are open and
free from blockage or debris. If the venting system is disas-
sembled for cleaning, it must be properly assembled and re-
sealed.
e) Check glass panel gasket, replace if necessary. It is
important that the glass seal be maintained in good condition.
Note: The appliance area must be kept clear and free from
combustible materials, gasoline and other flammable vapours
and liquids.
Periodically:
a) Viewing glass may be cleaned with fireplace glass cleaner.
b) Exterior porcelain enamel finish may be cleaned with
soap and water.
Note: Never use abrasive cleaner to clean this appliance.
Do not clean glass when hot.
Fig. # 1
THERMOCOUPLE
THERMOPILE
PILOT
FLAME
ELECTRODE
f i r e - p a r t s . c o m