Pacific Energy granville Installation And Operating Instructions Manual - First Fire
15
040805-24
GRNA
# 5055.651
First Fire
When lit for the first time, the appliance will emit a slight
odour for a couple of hours. This is due to the curing of paints,
sealants and lubricants used in the manufacturing process.
This condition is temporary. Open doors and windows to
ventilate area. Smoke and fumes caused by the curing process
may cause discomfort to some individuals.
Operation
The Granville Direct Vent Insert comes equipped with an
"ON-OFF" Rocker switch. This switch is conveniently lo-
cated near the upper right hand corner of the surround.
Once a pilot light has been established, and the gas control
knob turned to the "ON" position, the burner may be turned on
or off simply with the switch. An optional wall thermostat may
be installed to operate the burner automatically.
Primary Air Adjustment
This appliance is provided with primary air adjustment, which
affects flame height and flame quality by controlling the air
shutter opening. This adjustment is preset at the factory for the
best flame appearance for most installations. However,
adjustment is available to compensate for varying field condi-
tions, such as vent system height or altitude, that may affect
flame appearance.
The adjustment rods is accessible just to the left of the valve,
in behind the bottom louver, as shown in Fig. #23. Pushing the
rod upwards closes the shutter and increases flame height.
Manual HI-LO Flame Adjustment: (Fig #25)
The HI-LO burner control knob can be rotated in both direc-
tions, providing infinite control of gas flow rate to the burner
and therefore greater comfort control. The HI setting pro-
vides a maximum gas input, and rotating the knob clockwise
toward the LO setting will reduce the gas input to a minimum
setting.
Wall Thermostat (optional):
Set the wall thermostat to a comfortable temperature. Turn the
HI-LO burner control knob to a desired setting. As heat is
required, the Granville Direct Vent Insert will turn on or off
automatically, as needed.
Extend Shutdown:
To shutdown the appliance including the pilot, partially de-
press and turn gas control knob clockwise past “PILOT” to the
“OFF” position. DO NOT FORCE.
NOTE: The SIT control has an interlock device which does
not allow the pilot to be lit when the appliance is at operating
temperature. Let the appliance cool down (approx. 60 sec.)
before attempting to relight the pilot. DO NOT use force to
rotate the control knob.
Manual HI-LO Burner Control Knob
Fig. # 25
Fig. # 26
To Adjust: (See Fig. # 26)
1) Flip down bottom front louver.
2) Pull or push on adjustment rod to adjust flame.
3) Close bottom front louver.
Caution: Proper air shutter setting is a must. The flame should
not impinge on the top of the firebox. It should NEVER be set
to create sooting on internal parts and glass. Open air shutter
gradually until sooting stops.
Fig. # 27
Adjustment Rod
f i r e - p a r t s . c o m