Pacific Energy granville Installation And Operating Instructions Manual - Optional Blower
16
040805-24
GRNA
# 5055.651
Optional Blower
Installation:
The burner assembly must be removed for blower
kit installation. Follow "Burner Removal" section
for removal. Unpack and inspect blower kit.
1) Position the blower assembly over the two studs
located at the rear of the appliance so that the fan
motor is facing towards the front. Do not fasten
in place as no fasteners are required. (Fig. # 29)
2) Place the speed control junction box temporar-
ily in the right front corner of the appliance. The
junction box attaches to the underside of the
burner assembly, once in place. (Fig. #30)
3) Feed the power cord out through the plastic
grommet on the side of the appliance.
Electrical Supply:
Circulating air blower electrical rating: 115V, 60
Hz, 80 watts. (Fig #28) For your protection against
shock hazard, use only a properly grounded outlet
that will accept a three-pronged plug. Do not cut or
remove the grounding prong.
Consult local codes or, in the absence of local
codes, with the current CSA C22.1 Canadian Elec-
trical Code and in the USA with the National
Electrical Code, ANSI/NFPA 70 (latest Edition).
Speed
Control
G (green)
L1 (white)
L2 (black)
Snap Disc
Switch
Rocker
Switch
Fig. # 28
Blower
115 Volts
60 Hz
0.5 Amperes
Operation:
The variable speed circulating air blower is thermostatically
controlled for automatic operation, as well manually with a
convenient bypass switch.
Automatic: To operate the blower automatically, push the
rocker switch to the "AUTO" position and set the fan speed
control to desired setting. This will allow the blower to turn on
automatically once the Insert has come up to operating tem-
perature. It will also shut off shortly after the Insert is shut
down and cools. On and Off times will vary with installation
and location of fireplace.
Manual: To manually operate the blower, push the rocker
switch to the "MAN" position. This will bypass the tempera-
ture switch and allow full control of blower, independent of
the burner provided the speed control is set.