Pacific Energy granville Installation And Operating Instructions Manual - Installation
4
040805-24
GRNA
# 5055.651
Installation
The Granville Direct Vent Gas Insert installation and
venting must conform to the current CAN/CGA-B149.1
installation code (in Canada) or the National Fuel Gas
Code, ANSI Z223.1 -1988 (in the USA), and approved per
local codes. Only qualified (licensed or trained) personnel
should install this product.
Existing Fireplace
(Masonry or Factory Built)
The Granville Direct Vent Gas Insert is designed to be
installed into a masonry or a factory built zero clearance
fireplace. The masonry fireplace must be built according to
the requirements of the Standards for Chimneys, Fireplaces,
Vents and Solid Fuel Burning Appliances, NFPA 211 (Latest
Edition) or applicable National, Provincial, State or local
codes. The factory built zero clearance fireplace and its
chimney must be certified and meet applicable National,
Provincial, State or local codes.
In order to sufficiently accommodate the Granville Direct
Vent Gas Insert, the minimum size of the fireplace should be
28-3/8 inches wide, 20-3/4 inches high and 15 inches deep
(see Fig. #2).
The fireplace and its chimney should be swept and inspected.
The existing fireplace damper (if present) should be locked
open or removed completely if the opening is too small for two
- 3" flue liners to pass through.
Fig. # 3
Fig. # 2
B
20 3/4"
A
28 3/8"
5"
15"
17 7/8"
24 1/2"
Standard-size Surround
Plain and Embossed
Bevelled Panels ..............38 1/2" wide x 27 1/4" high
Over-size Surround
Plain Flat Panels .............44 3/4" wide x 30 1/2" high
A