Pacific Energy granville Installation And Operating Instructions Manual - Rocker Switch
7
040805-24
GRNA
# 5055.651
Make sure the marked inlet pipe is attached to the inlet side
(marked "I"), and the unmarked pipe is attached to the
outlet side (marked "E") of the connector plate.
7) Seal and secure inlet pipe with sealant and screws pro-
vided.
8) Slip the 3 1/2" pipe clamp loosely over the end of the flex
flue pipe. Slide the pipe over the collar (marked "E") of the
vent connector plate and clamp tightly in place. Secure in
place with screws provided. No additional seal is required.
9) Position vent connector plate over top of unit as the Insert
is pushed into the fireplace. Clip connector plate at the
back of the unit, tip down into position and attach in place
with screws previously removed. Leave the Insert extend-
ing a couple of inches out of the fireplace temporarily to
allow for proper surround placement.
Rocker Switch
No electrical connection is required for the gas system
operation. The self generating pilot provides current for the
optional remote wall switch.
The installation of a wall switch allows for manual remote
operation of fireplace, and automatic operation with a wall
thermostat. Use a switch or thermostat rated for millivolts.
Position the wall switch or thermostat so that a maximum of
25 feet of wiring from the switch to the fireplace is used. Use
18/2 thermostat wire. Connect the wall switch to the valve as
shown in Fig. #10.
Optional Wall Switch or Thermostat
Fig # 9
Fig # 10
Rocker Switch
TP
TP
TH
TH
TH
TP
TH
I P
T O
L
TP
E
A
P
O
T
L I
OF
N
O
F
30
20
10
O
I
H
L
O T
PIL
Thermostat
Wall
Switch
Rocker Switch
(located top right corner of surround trim)
Inlet
Pressure
Test Point
Manifold
Pressure
Test Point
Gas Valve
f i r e - p a r t s . c o m