Pacific Energy NEO 2.5 Installation And Operating Instructions Manual - page 15
141014-20
NEO 2.5 INSERT-A
15
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
Blowers
The Insert comes equipped with variable speed circulating
air blowers. The blower system is thermostatically controlled
for automatic operation, as well manually with a convenient
bypass switch.
Blowers Operation
Automatic: To operate the blowers automatically, push the
rocker switch to the “O” or AUTO position and set the fan speed
control to a desired setting.
This will allow the blowers to turn on automatically once the
Insert has come up to operating temperature. It will also shut
the blowers off after the fi re has gone out and the appliance
cooled to below a useful heat output range. On and Off times
will vary with installation and location of appliance.
Manual: To manually operate the blowers, push the rocker
switch to the “l” or MANUAL position and set the fan speed
control to a desired setting. This will bypass the temperature
switch and allow full control of the blowers.
Suggested settings:
- Combustion air control setting of "Low"(all the way to the
right), operate blowers speed control on “Low”.
- Combustion air control greater than "Low", operate blow-
ers speed control at desired setting.
Electrical Supply
Circulating air blower electrical rating: 115V, 60 Hz. 1AMP
For your protection against shock hazard, use only a properly
grounded outlet that will accept a three-pronged plug. Do not
cut or remove the grounding prong.
Consult local codes or in the absence of local codes, with the
current CSA C22.1 Canadian Electrical Code and in the USA
with the National Electrical Code, ANSI/NFPA 70 (latest edition).
Fig. # 12
L2 (black)
G (green)
L1 (white)
Speed
Control
Blowers
Thermo
Switch
By-pass
Rocker Switch