Pacific Energy NEO 2.5 Installation And Operating Instructions Manual - page 3
141014-20
NEO 2.5 INSERT-A
3
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
16”
406mm
16”(406mm)
11
1/2
”
292mm
15”
381mm
2”
51mm
8”
203mm
Clearances
Masonry or Factory Built Fireplace
The minimum required clearances to surrounding combustible
materials when installed into a masonry or factory built fi replace
are listed below and in Fig. #1.
Minimum Clearances to Combustibles
Adjacent Sidewall.................................**16 1/2 in. (419 mm)
...............................................................*15
in.
(381 mm)
Mantel(measured from surround brow).........16 in. (406 mm)
Top Facing...............................................16 in. (406 mm)
Side Facing...........................................**13 in. (330 mm)
.........................................................*11 1/2 in. (292 mm)
Ceiling................................................................68 in.(1.7m)
**Measured from door opening.
* Measured from edge of door.
Mantel or Top Facing
Side F
acing
Hearth
Adjacent
Wall
Fig. # 1
40"
1.02m
28 1/2"
724mm
21 3/4"
552mm
23 7/8"
606mm
19 3/4"
502mm
21 1/2"
546mm
7"
178mm
3"
76mm
33"
838mm
26 3/4"
680mm
21 7/8"
556mm
14 1/2"
368mm
33"
838mm
26 1/4"
667mm
*32"
813mm
*48"
1.2m
Safety
READ ALL INSTRUCTIONS BEFORE INSTALLING
AND USING THIS APPLIANCE. FAILURE TO FOLLOW
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
We strongly recommend that smoke detectors be installed.
If smoke detectors have been previously installed, you may
notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally
leaving the fi re door open. Do not disconnect the detectors.
If necessary, relocate them to reduce their sensitivity.
SAFETY NOTICE: If this stove is not properly installed, a
house fi re may result. For your safety, follow the installation
directions. Consult local building or fi re officials about restric-
tions and installation inspection requirements in your area.
The services of competent installer, certifi ed by the Wood
Energy Technical program (WETT) - in Canada, Hearth Edu-
cation Foundation (HEARTH) - in U.S.A. (or equivalent) are
strongly recommended.
Dimensions
SIDE FACING AND ADJACENT
WALL MEASURED FROM
EDGE OF DOOR
MINIMUM 68” FROM BASE OF
UNIT TO CEILING
*OVERSIZED SURROUND
DIMENSIONS
MANTEL DISTANCE
MEASURED FROM TOP OF
SURROUND BROW