Owner's Handbook Manual, Quick Start Manual, Owner's Handbook Manual, Setup & Operation, Operating Manual, Quick Start Manual, Commissioning Manual, Owner's Handbook Manual, Owner's Handbook Manual, Owner's Handbook Manual, Owner's Handbook Manual, Owner's Handbook Manual, Owner's Handbook Manual, Owner's Handbook Manual, Owner's Handbook Manual
Manual is about: Raymarine ST60 Tridata Instrument Owner's Handbook
of
52
22
ST60 Speed Instrument Owner’s Handbook
Power supply connections
SeaTalk systems
CAUTION:
When instruments are connected to SeaTalk, ensure that the
power supply for the SeaTalk 12 V line is protected by a 5 A fuse.
Systems with a large number of instruments on the SeaTalk bus may require
connections to the power supply from each end of the system (‘ring-main’ style),
to maintain sufficient voltage throughout the system.
This requirement depends on the total length of the cable run and the total
number of instruments in the system, as follows:
Cable run
No. of instruments
Power connections
Up to 10 m
13 maximum
26 maximum
1
2
Up to 20 m
7 maximum
13 maximum
1
2
Cable from transducer
White
Brown
Screen
Green
Red
Connections to ST60 Speed instrument
D4370-3
SeaTalk cable
SeaTalk cable