Raymarine ST60 Tridata Owner's Handbook Manual - 4.4 Dealer Calibration
34
ST60 Speed Instrument Owner’s Handbook
8. Carry out one of the following actions:
• If you are satisfied with the results of the first calibration run, press the
speed
and
trip
keys together, to store the new calibration factor, exit
speed calibration and return to the Instrument status screen.
• If you want to carry out a second calibration run:
i.
Press
trip
to start a second calibration run (see
sheet 2
of the
Speed
calibration
flow chart).
ii. Use the procedure described above in steps 4 to 7, to complete the
second run. At the end of the second run, the text END alternating
with the new calibration factor is displayed at the top of the screen.
iii. Press the
speed
and
trip
keys together, to store the new calibration
factor, exit speed calibration and return to the Instrument status
screen.
Leaving Intermediate calibration
Hold down the
speed
and
trip
keys for 2 seconds to save your settings, exit
Intermediate calibration and resume normal operation.
4.4 Dealer calibration
The Dealer calibration procedure (see
Dealer calibration
diagram) enables the
following parameters to be set:
• User calibration on/off.
• Speed response.
• VMG response.
• Boat show mode on/off.
Dealer calibration also gives access to the Factory defaults screen. This enables
you to re-apply the factory settings if you want to reset the instrument to a known
operating condition.
To commence Dealer calibration, hold down the
speed
and
trip
keys together for
approximately 12 seconds, to select the Dealer calibration entry page. Press the
timer
and
reset
keys together, to proceed with the calibration, then use the
speed
key to proceed from screen to screen as calibration progresses.
User calibration on/off
Press the
timer
or
reset
keys to toggle the User calibration either ON or OFF as
required. With OFF selected, User calibration and Intermediate calibration are
both disabled.