SmartVent Synergy 190 User Manual - page 45
42
Maintenance
CLEANING THE COLOUR TOUCH SCREEN CONTROLLER
1) Turn your Synergy system OFF (refer to page 8 for instructions on turning your
system OFF).
2) Clean the control screen by gently wiping the surface with a slightly dampened
tissue moistened with water only, cleaning solution is not recommended.
DO NOT spray cleaning solutions or water onto the control screen as it is NOT
WATERPROOF.
3) Turn your Synergy system back ON (refer to page 9 for instructions on turning
your system ON)
MAINTENANCE OF THE HEAT RECOVERY UNIT
We recommend that the Heat Exchanger Core is cleaned
once a year by completing the following steps:
1) Turn your Synergy system OFF (refer to page 8 for instructions on turning your
system OFF
).
2) Remove the front panel (black
plastic cover). Unscrew the four
screws on the front of the unit.
Carefully remove the front half of the
unit and put to one side.
3) Carefully remove the heat
exchanger core.
4) Create a mild detergent solution
(1 x teaspoon of washing up liquid to
a 9L bucket of warm water). Soak the
heat exchanger core in this liquid for
one minute.
5) Rinse thoroughly using clean water until the water runs clear and there is no
solution residue left on the inner plates of the heat exchanger core. Allow to fully dry
before proceeding.
6) Reassemble the unit, taking care not to damage the rubber seals.
7) Turn your Synergy system back ON (refer to page 9)