8 - CONTROL UNIT
PD15 is provided with a display that, not only makes
programming simple, but also allows a continuous monitoring of
the input statuses; in addition, thanks to a menu structure, the
working schedule and the operation logic can be set easily.
In compliance with the European standards concerning
electrical safety and electromagnetic compatibility
(EN 60335-1, EN 50081-1 and EN 50082-1) it has been
equipped with the low voltage circuit total electric insulation
(motors included) from the network voltage.
Other characteristics:
• Led lighting integrated on the control unit board
• Automatic control for zero-current relay switching
• Power adjustment with current chopping
• Obstacle detection by motor current monitoring
• Automatic learning of the operation time
• Specific entrances for end stops
• Tests for safety devices (photocells and ribbons)
before each opening
• Deactivation of safety inputs through the configuration
menu: no jumper is required for terminals concerning safety
devices that have not been installed, yet. You will only need
to disable this function from its relevant menu.
• Control unit programming can be locked through the optional
CL1+ key
m
WARNING: Installation of control unit and safety
devices must be carried out with power disconnected.
8.1 - POWER SUPPLY
The control unit must be fed by a electric line
(85 ÷ 245 Vac / 50 ÷ 60 Hz), protected by a differential
magnetothermal switch complying with the law provisions in
force.
Connect power supply cables to terminals
L
and
N
of PD15
control unit.
Connect the electric system ground to the terminal
m
WARNING:
the incorrect connection of these terminals may result in
permanent damages to the control unit
8.2 - COURTESY LIGHTS
Thanks to the output COURTESY LIGHT the control unit allows
the connection of an electric appliance (e.g. courtesy light or
electric lock), controlled automatically or by means of the special
transmitter key.
The output COURTESY LIGHT is a simple N.O. contact with no
power supply.
Connect the cables to terminals
B1
and
B2
.
8.3 - LOW VOLTAGE LIGHT OUTPUT
The PD15 control unit has a 24 Vdc output that allows
connection of a maximum load of 3W.
This output can be used to connect a warning light, indicating
the status of the gate, or for a low voltage flashing light
(e.g. LUMOS-24V).
Connect the low voltage signal light or flashing light wires to
terminals
J7
and
J9
.
8.4 - SAFETY RIBBONS
The control unit PD15 is equipped with a specially provided
input to control safety ribbons.
Tripping during opening causes the door to close back for
3 seconds.
Tripping during closing causes the door to fully reopen.
This input can control either the classic edge with N.C. contact,
or the conductive rubber ones with nominal resistance 8,2 kohm.
Connect the cables of the safety ribbons between terminals
J1
and
J4
of the control unit.
m
WARNING:
• When using more ribbons with N.C. contact, the inputs have
to be series connected.
• If using more conductive rubbers, the outputs have to be
cascade connected and only the last one has to be