Stop Input
This menu permits to select the functions associated to the
command of STOP.
no
The input STOP is not available.
ProS
The input STOP stops the door: pressing the command START
the door continues the motion.
inuE
The command STOP stops the door: at the next START the
door starts moving in the opposite direction.
NOTE:
during the pause, the STOP command will stop the pause time
count, the next START command will always close the door
Photocell input
This menu allows enabling the input for photocells (see paragraph
“Installation”).
no
input disabled (ignored by the control unit).
No jumper with the common is required.
CF.CH
input enabled even at standstill door too: the opening
movement does not start if photocell is interrupted.
CH
input enabled for the closing phase only
m
Warning: if you select this option, you must disable
photocell test.
Blinker during pause time
Blinker usually operates during the door motion only; however, if this
function is enabled, blinker will be on during the pause time too
(door open with automatic closure active).
Start input function
This menu allows selecting input operation modes (see paragraph
“Activation inputs”):
StAn
Start and Pedestrian Start input standard operation, according
to menu setups.
no
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode.