19 - TESTING AND START-UP
In implementing the automation device, these are the most important
steps for guaranteeing maximum safety.
V2 recommends the application of the following technical standards:
• EN 12445 (Safety in the use of automated closures, test
methods)
• EN 12453 (Safety in the use of automated closures,
requirements)
• EN 60204–1 (Safety of Machinery, electrical equipment of
machines, part 1: general principles)
In particular, with reference to the table in the section “PRELIMINARY
CHECKS and IDENTIFICATION OF THE TYPE OF USE” in the majority of
cases, it will be necessary to measure the impact force, in accordance
with the provisions of EN 12445.
Adjusting the operating force is possible by programming the electronic
circuit board, and the impact force profile should be measured using an
appropriate device (itself also certified and subjected to annual
calibration) capable of tracing the force-time graph.
The result should be in compliance with the following maximum values:
For a comprehensive guide on the installation of automation devices and
the documentation to be prepared, we recommend use of the guides
issued by the Italian association UNAC, obtainable from
www.v2home.com
20 - MAINTENANCE
Maintenance should be performed in full compliance with
the safety instructions described in this manual and in
accordance with current legal and regulatory provisions.
The recommended interval between each maintenance
operation is six months, the checks involved should at least
relate to:
• the perfect efficiency of all warning devices
• the perfect efficiency of all safety devices
• measurement of the door operating forces
• the lubrification of mechanical parts on the automation
device (where necessary)
• the state of wear of the mechanical parts on the
automation device
• the state of wear of the electrical cables on the
electromechanical actuators
The result of each check should be recorded in a door
maintenance log.
21 - DISPOSAL OF THE
PRODUCT
As for the installation operations, even at the end of this
product’s life span, the dismantling operations must be
carried out by qualified experts.
This product is made up of various types of materials:
some can be recycled while others need to be disposed
of. Find out about the recycling or disposal systems
envisaged by your local regulations for this product
category.
Important!
– Parts of the product could contain
pollutants or hazardous substances which, if released into
the environment, could cause harmful effects to the
environment itself as well as to human health.
As indicated by the symbol opposite, throwing away this
product as domestic waste is strictly forbidden. So
dispose of it as differentiated waste, in accordance with
your local regulations, or return the product to the
retailer when you purchase a new equivalent product.
Important!
– the local applicable regulations may
envisage heavy sanctions in the event of illegal disposal
of this product.
Dynamic
IMPACT force
Static CRUSHING
force
Time
Force