The light bulb fitted to this heater is a long life compact fluorescent type, but due to the
indeterminate life span and ease of replacement, it is specifically excluded from the
guarantee.
To replace the light bulb.
1.
To gain access to the light bulb, remove the loose coals from the fuel support and
place them onto an old newspaper or plastic bag. This will prevent them from marking
the surface.
2.
Remove the lower fascia, (On the Adage heater it will be necessary to remove the
whole magnetic front fascia), see figure 2 & 3 and the section headed “ Removing the
fascia”.
3.
Note the position of the dark area on the light bulb shroud. Remove the light bulb
shroud by sliding it to the left.
4.
Replace the light bulb with an 18 - 20 Watt (maximum) Edison screw, compact
fluorescent light bulb eg. ‘Philips Ecotone’. Do not use standard tungsten light bulbs
due to the excessive heat.
5.
Refit the light bulb shroud into the position noted earlier. Refit the lower fascia /
magnetic fascia and refit the coals.
2. My heater is on but there is no light or heat.
The first thing to do is check the wall socket. To do this plug in a known working
appliance. If the appliance you have plugged in works then there is a good chance that
the problem lies with the 13Amp fuse in the heater plug. If either fuse or socket is
suspected, have them checked by an electrician.
3. My heater is on but there is no heat.
A cut out device is fitted to the heater to prevent damage due to over heating. If it
operates due to an obstruction in the airflow, the heater must be turned off and allowed
to cool for 15 minutes and the obstruction removed before restarting.
Page 16