Control Channel Functions
The following control actions must be accomplished with zero time transition or with timing disabled.
Discrete values must be used and not manual controls such as faders or encoders.
To use control channel functions:
Step
1. Select an action to be sent.
Step
2. Set control channel value for desired action (for example, 84 for reset). Hold value for 3
seconds.
Note: A numerical keypad is required for sending values. An encoder or fader does not allow for a
quick value change, which is required to affect the control functions.
Step
3. Set control channel value to zero. (This must occur without any scaling values. Action will
be voided if other values are detected between action value and zero.)
Note: The Snap control channel function takes place immediately, and does not require the control
value be set to zero after three seconds. For more information on Snap functionality see
.
Table 3-8: Control Channel Functions
Control
Channel
Function
Control Channel Value
% Value
For 3 Secs
or Greater
After
3 Secs
Display On
1
1-4
0
Snap On
9
20-25
N/A
Snap Off
13
30-35
N/A
Luminaire Reset
33
81 - 87
0
Lamp Off
66
165 - 171
0
Lamp On
99
249 - 255
0