0 2 . 9 6 7 1 . 0 0 0 1 F
07-M ay- 03
85
B2M2
Ambr
SAct
Aux Board 2, Motor 2,
Amber,
Sensor Always Active
Amber power not connected, and amber
aligned with sensor
- Connect Amber power at motors
BRD1
NO
COMM
Aux Board 1 Communication
Failure
Aux input connector (J5) not connected
to either aux board
- Connect aux input connector (J5) to
either aux board
Jumper/bridge connector (J1) between
aux boards not connected
- Install jumper/bridge connector (J1)
between aux boards
BRD2
NO
COMM
Aux Board 2 Communication
Failure
Aux input connector (J5) not connected
to either aux board
- Connect aux input connector (J5) to
either aux board
Jumper/bridge connector (J1) between
aux boards not connected
- Install jumper/bridge connector (J1)
between aux boards
LAMP
STRK
FAIL
Lamp Strike Failure
Lamp failed to strike after repeated
attempts
- Replace lamp
PAN
ENCR
FAIL
Pan Encoder Failure
Main board pan/tilt connector (J9)
disconnected
- Connect main board pan/tilt
connector (J9)
Pan motor disconnected
- Connect pan motor power
Encoder faulty
- Replace pan end-of-travel/encoder
sensor assembly
PAN
NO
SENS
Pan Sensor Not Found
EOT flag attached to large pulley is not
engaging the EOT sensor
- Ensure flag is attached to the large
pulley
- Ensure that flag passes through the
sensor at a depth sufficient to
engage the sensor beam
Pan belt disconnected, extremely loose
or not installed properly
- Properly install belt between pan
motor and large pulley
PAN
SENS
ACTV
Pan Sensor Always Active
Main board pan/tilt connector (J9)
disconnected
- Connect main board pan/tilt
connector (J9)
End-of-travel sensor connector (J2)
disconnected
- Connect end-of-travel sensor
connector (J2)
Table A-2: Troubleshooting Guide (Continued)