Vega VEGAPULS 69 Quick Setup Manual

Manual is about: Radar sensor for continuous level measurement of bulk solids

Summary of VEGAPULS 69

  • Page 1

    Quick setup guide radar sensor for continuous level measurement of bulk solids vegapuls 69 4 … 20 ma/hart - four-wire document id: 47255.

  • Page 2: Contents

    2 contents vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 contents 1 for your safety 1.1 authorised personnel ....................................................................................................... 3 1.2 appropriate use .........................................................

  • Page 3: 1  For Your Safety

    3 1 for your safety vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 1 for your safety 1.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with th...

  • Page 4

    4 1 for your safety vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 1.5 ce conformity thedevicefulfillsthelegalrequirementsoftheapplicableecguide- lines.Byaffixingthecemarking,weconfirmsuccessfultestingofthe product. Youcanfindthececertificateofconformityinthedownloadsection of our homepage...

  • Page 5

    5 1 for your safety vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 pleasehelpusfulfillthisobligationbyobservingtheenvironmental instructions in this manual: • chapter "packaging, transport and storage" • chapter "disposal".

  • Page 6: 2  Product Description

    6 2 product description vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 2 product description 2.1 configuration thetypelabelcontainsthemostimportantdataforidentificationand use of the instrument: 2 1 14 15 16 17 13 12 11 5 3 6 4 7 8 9 10 fig. 1: layout of the type label (example) 1 instrume...

  • Page 7

    7 2 product description vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 • download the smartphone app "vegatools" from the "apple app store" or the "googleplaystore" • scan the data matrix code on the type label of the instrument or • enter the serial number manually in the app.

  • Page 8: 3 Mounting

    8 3 mounting vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 3 mounting 3.1 mounting preparations, mounting strap the strap is supplied unassembled and must be screwed to the sensor before setup with three hexagon screws m5 x 10 and spring washers. Max. Torque, see chapter "technicaldata". ...

  • Page 9

    9 3 mounting vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 200 mm (7.87") fig. 3: mounting the radar sensor on the vessel top if you cannot maintain this distance, you should carry out a false signal storage during setup. This applies particularly if buildup on the vessel wall is expected...

  • Page 10

    10 4 connecting to power supply vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 4 connecting to power supply 4.1 connection the voltage supply and signal output are connected via the spring- loaded terminals in the housing. Connection to the display and adjustment module or to the interface...

  • Page 11

    11 4 connecting to power supply vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 7. Connect the screen to the internal ground terminal, connect the outer ground terminal to potential equalisation in case of power supply via low voltage 8. Connect the lead cable for power supply in the same w...

  • Page 12

    12 4 connecting to power supply vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 power supply 4...20ma active passiv e commo n is gn d 5 1 /l /n 2 + ( ) (-) 6 7 8 fig. 6: connection compartment with double chamber housing with low voltage terminal function polarity 1 voltage supply +/l 2 vol...

  • Page 13: Module

    13 5 set up with the display and adjustment module vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 5 set up with the display and adjustment module 5.1 insert display and adjustment module the display and adjustment module can be inserted into the sensor andremovedagainatanytime.Youcanchoose...

  • Page 14

    14 5 set up with the display and adjustment module vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 carry out the following steps in the below sequence. Youcanfind"extendedadjustment" in the next sub-chapter. 1. Measurement loop name inthefirstmenuitemyouassignasuitablemeasurementloopname. P...

  • Page 15

    15 5 set up with the display and adjustment module vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 thequicksetupisfinished. 5.3 parameter adjustment - extended adjustment since the radar sensor is a distance measuring instrument, the distance from the sensor to the product surface is measur...

  • Page 16

    16 5 set up with the display and adjustment module vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 information: this is generally recommended, however, for use of the asset management functions it is absolutely necessary. Saving should be carried out with a very low level. The function "ech...

  • Page 17

    17 5 set up with the display and adjustment module vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 4. Confirmagainwith[ok] and enter the actual distance from the sensor to the product surface. 5. All interfering signals in this section are detected by the sensor andstoredafterconfirmingwith...

  • Page 18: 6 Supplement

    18 6 supplement vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801 6 supplement 6.1 technical data electromechanical data - version ip 66/ip 67 cable gland m20 x 1.5 or ½ npt wire cross-section (spring-loaded terminals) Ʋ massive wire, stranded wire 0.2 … 2.5 mm² (awg 24 … 14) Ʋ stranded wire ...

  • Page 19

    19 notes vegapuls 69 • 4 … 20 ma/hart - four-wire 47255-en-140801.

  • Page 20

    Printing date: vega grieshaber kg am hohenstein 113 77761 schiltach germany 47255-en-140801 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subjec...