39
GB
Cleaning the unit (shutting down)
1
2
3
4
5
6
7
8
8.3
Cleaning Airless spray gun
– Rinse Airless spray gun with an appropriate cleaning agent.
– Clean tip thoroughly with appropriate cleaning agent so that
no coating material residue remains.
– ThoroughlycleantheoutsideoftheAirlessspraygun.
Intake filter in Airless spray gun (fig. 16)
Dismounting
1. Pull protective guard (1) forward vigorously.
2. Screw handle (2) out of the gun housing. Remove intake filter
(3).
3. Intake filter congested or defective – replace.
Mounting
1. Place intake filter (3) with the long cone into the gun housing.
2. Screw handle (2) into the gun housing and tight en.
3. Snap in protective guard (1).
1
2
3