WAGNER Plast Coat 25 Operating Manual - Plast Coat 25 · 35
37
Plast Coat 25 · 35
GB
placIng Into operatIon
Preparing the mortar spraying machine
Only work with the safety grill inserted!
Recommended lubricant for the mortar hose
Water is not a satisfactory lubricant.
Danger of blockages!
Synthetic resin products –> synthetic resin
dispersion
PCC systems
–> cellulose paste
Spray lance with automatic control
• Openmaterialtap(3,fig.15)onthespraylance.Themortar
spraying machine will switch on.
Spray lance without automatic control
• Openmaterialtap(3,fig.16)onthespraylance.Pressremote
control switch (1, fig. 16). The mortar spraying machine will
switch on.
Spray lance with automatic control
• Whenthesyntheticresindispersionorcellulosepastehas
been pumped into the mortar hose – turn off device, turn
switching sleeve (1, fig. 15) by 90° in a clockwise direction as
far as it will go.
• Closematerialtap(3,fig.15).
extension cable PlastCoat 25
The cross section of the cable must be min.
3 x 2.5 mm. Unwind extension cable com-
pletely. Make sure that the couplings and
plugs are in complete working order.
Arrange the mains cable so that there is no
danger of it being tripped over.
Protect against damage, e.g., caused by it
being run over.
• Beforeconnectingtothemainsmakesurethatthemains
voltage is in accordance with the details on the rating
plate.
• Onlyconnecttothemainssupplyusingaspecialdistribut-
ing point, e.g. using a site distribution system with fault cur-
rent protection with INF ≤ 30 mA.
• Connectmortarsprayingmachinetothemainssupply.
• Fill2–3lsyntheticresindispersionorcellulosepasteintothe
receptacle.
• Caution: set changeover switch (4, fig. 14) to „0“ before turn-
ing on the master switch (1, fig. 14).
the pump is switched on, even if the feed rate
regulator is at position „0“.
• Turnmasterswitch(1,fig.14)to„1“,theindicatorlampwill
show that the machine is ready for operation.
• Setfeedrateregulator(3)to„5“.
• Turnchangeoverswitch(4)to„AUTO“(remotecontrolusing
spray lance).
• Holdspraylanceoveranemptybucket.
7
1 6
2
8
3
5
4
extension cable PlastCoat 35
The cross section of the cable must be min.
5 x 2.5 mm. Unwind extension cable com-
pletely. Make sure that the couplings and
plugs are in complete working order.
2
3
4
1