WAGNER Plast Coat 25 Operating Manual - Plast Coat 25 · 35
38
Plast Coat 25 · 35
GB
Spray lance without automatic control
• Openmaterialtap(3,fig.16).
• Turnondevicewithremotecontrolswitch(1,fig.16).
• Coatingmaterialwillbepumpedintothemortarhose.
• Pumpsyntheticresindispersionorcellulosepastefromthe
mortar hose into a bucket.
• Assoonascoatingmaterialstartscomingoutofthespray
lance – turn off device using remote control and close mate-
rial tap on the spray lance.
• Holdspraylanceoverthereceptacle.
• Openmaterialtap(3,fig.15and16)andturnondeviceus-
ing remote control.
• Setthefeedrateregulator(3,fig.3,page31)totherequired
feed rate.
• Turnoffdeviceusingremotecontrolandclosematerialtap
(3, fig. 15 and 16).
• Fasten mortar hose using hose holder to the frame (each
connecting hose separately).
Starting the spraying procedure
• Openairtap(2,fig.16and17)andmaterialtap(3,fig.15
and 16) on the spray lance.
Spray lance without automatic control
Turn device on using remote control switch (1, fig. 16).
end of the spraying procedure
Spray lance with automatic control
• Turnswitchingsleeve(1,fig.15)90°clockwiseasfarasitwill
go.
• Wait3–5seconds.
• Closematerialtap(3,fig.15).
Spray lance without automatic control
• Pressremotecontrolswitch(1,fig.16)onmortarhose.
• Wait3–5seconds.
• Closematerialtap(3,fig.16).
Spray lance with automatic control (fig. 15)
Spray lance without automatic control (fig. 16)
8
GeNeRAl ReQuIReMeNtS FOR
APPlICAtION
teCHNOlOGy
Spraying technique
Guide the spray lance at a uniform distance of 30 – 60 cm from
the object when spraying. If you do not do this, you will not
achieve a regular spray pattern. The spray pattern is depend-
ent upon the type of material, material consistency, tip size,
do not kink the mortar hose!
Protect it against damage e.g., resulting
from it being run over or from sharp ob-
jects.
• Closeairtap(2,fig.15).
Noncompliance with the above instruc-
tions will result in additional wear of the
material tap.
Noncompliance with the above instruc-
tions will result in additional wear of the
material tap.
• Closeairtap(2,fig.16).
general requIrements for applIcatIon technology
3
2
1
2
1
3
Spray lance without automatic control
• Whenthesyntheticresindispersionorcellulosepastehas
been pumped into the mortar hose – turn off device with
remote control switch (1, fig. 16).
• Closematerialtap(3,fig.16).
• Checkviscosityofthecoatingmaterial.
• Fillcoatingmaterialintothereceptacle.Withmineralcoat-
ing materials only fill the receptacle to half full.
Spray lance with automatic control
•Openmaterialtap(3,fig.15).
•Thecoatingmaterialwillbepumpedintothemortarhose.