Waldorf RN8410G Installation And Operation Manual - page 25
23
Gas Conversion and Specifications
Gas Specifications
- Australia:
- New Zealand:
- UK Only:
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
* - Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to ‘details in this section for information).
Natural Gas
LP Gas (Propane)
Open Burners
Main Burner Injectors
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35 0.23
Main Burner
Ø 2.40mm
Ø 1.40mm
Pilot Burner
0.35 0.23
Low Fire
0.90mm 0.55mm
Burner Aeration Setting
Fully Open
10mm
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Regulator Cap Screw
Oven
Natural Gas (G20)
Propane (G31)
Open Burner
Main Burner Injectors
Ø 2.30mm
Ø 1.40mm
Pilot Burner ('PF' Models Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35 0.23
Main Burner
Ø 2.40mm
Ø 1.40mm
Pilot Burner
0.35 0.23
Low Fire
Ø 0.90mm
Ø 0.55mm
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
9.5 mbar
26 mbar
Gas Regulator Cap Screw
Oven
Burner Aeration Setting
Fully open
10mm
Natural Gas
LP Gas
Open Burners
Main Burner Injectors
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35 0.23
Main Burner
Ø 2.40mm
Ø 1.40mm
Pilot Burner
0.35 0.23
Low Fire
0.90mm 0.55mm
Burner Aeration Setting
Fully Open
10mm
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Regulator Cap Screw
Oven