Waldorf RN8410G Installation And Operation Manual - page 26
24
Gas Conversion and Specifications
- All Other Markets:
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to information in this section for further details.
Natural Gas
Town Gas (**)
Open Burner
Main Burner Injectors
Ø 2.45mm
Ø 4.50mm
Pilot Burner ('PF' Models only)
0.30 0.60
Griddle
Main Burner
Ø 2.10mm
Ø 3.40mm
Pilot Burner
0.35 0.60
Burner Aeration Setting
Fully open
Fully open
Oven
Main Burner
Ø 2.40mm
Ø 4.50mm
Pilot Burner
0.35 0.60
Low Fire
Ø 0.90mm
Ø 1.60mm
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
1.13 - 3.40 kPa
0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa
0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner Operating
Pressure specified).
LP Gas (Propane)
Butane
Open Burner
Main Burner Injectors
Ø 1.50mm
Ø 1.40mm
Pilot Burner ('PF' Models only)
0.20
Griddle
Main Burner
Ø 1.30mm
Ø 1.20mm
Pilot Burner
0.23
Burner Aeration Setting
Fully open
Oven
Main Burner
Ø 1.40mm
Ø 1.30mm
Pilot Burner
0.23
Low Fire
Ø 0.55mm
Burner Aeration Setting
10mm
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Regulator Cap Screw