WEG MW500 User Manual - page 27
MW500 | 21
Keypad (HMIR) and Basic Programming
- English -
4.3 OPERATING MODES OF THE HMIR
The HMIR must be configured via hardware on S10 DIP-switch before the operation.
The S10 is shown in
figure A.2
of
Appendix A
. For recognizing the HMIR the drive can
be adjusted as shown in
table 4.1
.
Table 4.1: S10 DIP-switches configuration
Switches
Status
S1
ON
S2
OFF
S3
OFF
S4
OFF
The monitoring mode allows the user to view up to three variables on the main display,
secondary display and bar graph. Such fields of the display are defined in
figure 4.2
.
The setting mode is composed of three levels: Level 1 allows the user to select the Menu
items in order to browse the parameters. Level 2 allows browsing the parameters of the
group selected by level 1. Level 3 allows the modification of the parameter selected in
Level 2. At the end of this level, the modified value is saved or not if the key ENTER or
ESC is pressed, respectively.