Table B.2: Input and output currents, overload currents, carrier frequency, surrounding air
temperature and power losses specifications
Inverter
Output
Rated
Current
Overload
Currents
Rated
Carrier
Frequency
Nominal Inverter
Surrounding
Temperature
Input
Rated
Current
Inverter
Power
Losses
(Inom)
1 min
3 s
(fsw)
IP66 for
Integrate
Mounting
IP66
for Wall
Mounting
Surface
Mounting
[Arms] [Arms] [Arms]
[kHz]
[ºC / ºF]
[ºC / ºF]
[Arms]
[W]
MW500B06P5T4
6.5
9.8
13
4
50 / 122
40 / 104
6.45
109
MW500B10P0T4
10
15
20
4
50 / 122
40 / 104
9.30
168
Table B.3: Conducted and radiated emission levels, and additional information
Values to be defined.
Inverter Model
Without External RFI Filter for
Decentralized Installation
With External RFI Filter
Conducted Emission
– Maximum Motor
Cable Length
Radiated
Emission
External RFI
Filter Part
Number
(manufacturer:
XXX)
Conducted Emission
– Maximum Motor
Cable Length
Radiated
Emission -
Category
Category
C3
Category
C2
Category
Category
C2
Category
C1
Without
Metallic
Cabinet
MW500B06P5T4...C2...
-
-
-
-
-
-
-
MW500B10P0T4...C2...
-
-
-
-
-
-
-