Logging in on the 3M Clean‑Trace Luminometer with a PIN
When the 3M Clean-Trace Luminometer is turned on, it automatically does a diagnostic check. If the diagnostic check is
within the required limits, the login screen appears.
1. The Default User is automatically logged in. Tap
[Login].
• Or, if you set up Users using 3M Clean-Trace Hygiene Management Software, to select your User name, tap select
User
and tap your User name. Tap
[Login].
• Use the number pad to enter your 4 digit PIN. As you enter each number, an asterisk (*) appears on the screen. Then
tap Enter
.
• If you enter a number incorrectly, tap Delete
to remove the number, and then enter a correct number.
• If you fail to enter your PIN correctly, you can make two more attempts. After three failed attempts, your user name
and PIN are locked out. Wait 5 minutes for your user name and PIN to clear automatically.
• If your user name does not appear or your PIN does not work, contact your supervisor.
• When you have correctly entered your user name and PIN, tap Enter
.
2. The New Testing screen displays
Unplanned Test and the Sample Plans. You can start a new run of a sample plan or
start new unplanned testing. To return to this screen at any time, tap Home
.
• For more information, refer to the Performing Unplanned Testing or the Performing Tests on Test Points in Sample
Plans sections in this User Manual for more information.
Waking the 3M Clean‑Trace Luminometer from Sleep Mode
The 3M Clean-Trace Luminometer conserves battery power if the touch screen or the cursor control buttons are inactive.
After 5 minutes of inactivity, the 3M Clean-Trace Luminometer goes into Sleep mode and the screen darkens. After 2
additional hours of inactivity, the 3M Clean-Trace Luminometer automatically shuts down and must be powered on again
before use. Refer to the Switching the Power on section of this User manual for more information.
1. To wake the 3M Clean-Trace Luminometer from Sleep mode, press and hold the up arrow
button on the cursor
control pad for 3 seconds.
2. The screen displays the information that appeared before the Sleep mode began so you can continue working.
• If the 3M Clean-Trace Luminometer does not wake from the Sleep mode:
The 3M Clean-Trace Luminometer might be turned off. Press and hold the on/off
button for 3 seconds to
turn it on. Refer to the Switching the Power on section in this User Manual for more information.
The battery might be completely discharged. Refer to the Charging the Battery section in this User Manual for
more information.
The 3M Clean-Trace Luminometer might need repair. Contact your 3M Representative for more information.
Using the Swab Sensor and Vertical Position Sensor
As soon as measurement of a 3M Clean-Trace Test is complete, remove the 3M Clean-Trace Test from the Luminometer
chamber. If a test remains in the 3M Clean-Trace Luminometer chamber for more than 30 seconds, the Swab Sensor
notifies you to remove it.
• Keep the 3M Clean-Trace Luminometer upright whenever a test is in the chamber to ensure accurate results and
avoid spillage of reagents, which could damage the sensitive components of the instrument. If the 3M Clean-Trace
Luminometer is held at greater than 68 degrees from vertical when a test is in the chamber, a tilt symbol
notifies
you the test measurement was cancelled. Tap
[OK], then hold the 3M Clean-Trace Luminometer in a vertical position
and measure the test again.
Logging out from the 3M Clean‑Trace Luminometer
1. Tap Settings
.
2. Tap
[Log Out]. The Login screen appears. Refer to the Logging in on the 3M Clean‑Trace Luminometer section in this
User Manual for more information.