36 | Product Options
Aprisa SR User Manual
Switch Over
The active radio is determined explicitly by which radio receives data on its RS-232 serial port.
The switching and blocking criteria used for the standard Protected Station do not apply. This means that
events and alarms on the unit are not used as switching criteria.
Configuration Management
The Primary and Secondary radios are managed with the embedded web-based management tool,
SuperVisor (see ‘Managing the Radio’ on page 59) by using either the Primary or Secondary IP address.
Configuration changes in one of the radios will automatically be reflected in the partner radio.
Changes to the Network Table are automatically synchronized from the active radio to the standby radio
but the Network Table is only visible on the active radio.