Terminal > Parameters
The Parameters page is a dynamic page that will display the parameters associated with the active
alarms, set on ‘Events > Events Setup’ on page 137. The screenshot below shows a small amount of
monitored alarms as an example.
The following is a list of alarm events that are monitored:
Monitored Parameter
Unit
Event ID
Event Display Text
Current Temperature
Celsius
4
Temperature Threshold
Last RX Packet RSSI
dBm
7
RSSI Threshold
Last Sample RX CRC Error
Ratio
9
RX CRC Errors
Last Sample RF RX Data
Count
34
RF No Receive Data
Last Sample Eth1 RX Data
Count
10
Port 1 Eth No Receive Data
Customer Eth1 Data RX Errors
Ratio
11
Port 1 Eth Receive Errors
Customer Eth1 Data TX Errors
Ratio
12
Port 1 Eth Transmit Errors
Last Sample Eth2 RX Data
Count
35
Port 2 Eth No Receive Data
Customer Eth2 Data RX Errors
Ratio
36
Port 2 Eth Receive Errors
Customer Eth2 Data TX Errors
Ratio
37
Port 2 Eth Transmit Errors
Last Sample Serial RX Data
Count
13
Serial Data No Receive Data
Customer Serial Data RX Errors
Ratio
14
Serial Data Receive Errors
Last TX Packet PA Current
mA
None
Last TX Packet AGC
mV
None
Last TX Packet Reverse Power
dB
None
Current RSSI
dBm
None
If an associated alarm event occurs, the Parameters table will display the current value for that
parameter. The refresh time is 12 seconds.