Bircher Reglomat PrimeTec User manual

Manual is about: Combined microwave (motion)/active infrared (safety) sensor for activating and protecting automatic pedestrian sliding doors

Summary of PrimeTec

  • Page 1

    Page 1 prime tec user manual introduction i j k h o g l n combined microwave (motion)/active infrared (safety) sensor for activating and protecting automatic pedestrian sliding doors 1 box contents 1.1 - ladder - tape measure - level - wire cutter - 4 gauge (5 mm dia.) wire stripper for cable sleeve...

  • Page 2

    Mounting the sensor 3 ensure door header cover- plate is always in place and held tightly by screws. Mount the primetec rain cover, (ptcr) if sensor is exposed to rain. Obstruction can affect performace. Ensure safety & motion sensors have unobstructed views. Mount sensor away from fluorescent or hi...

  • Page 3

    Insert the female plug on the gray cable into the male receptacle on the sensor. Ensure the plug is fully inser- ted. Wiring the sensor 3.3 template middle of door opening position the removable self-adhesive mounting template on the door header frame in the middle of the opening (see illus- tration...

  • Page 4

    Sensor must be programmed for this wiring configuration. Press and hold the black value button for 8 seconds to separate motion & safety outputs. For more details, please see section 8. This option may only be used with the included gray cable. Electrical connections 4 4-wire connection: standard op...

  • Page 5

    A b c d initialization safety curtain adjustment 6 5 the alternate flashing led’s indicate the initialization (teach-in) of the sensor. (duration 10 - 15 sec.) the led’s will then remain continuously lit for 10 more seconds. Please see below for lcd screen readouts. Remove all foreign objects that a...

  • Page 6

    Standard field 6.2 adjusting the safety curtain distance from the door –– ++ 0° 7° -5° 7.1 changing the motion field pattern page 6 1/8 turn ≈ 1° ≈ 1” please refer to current published ansi standard for exact measure- ments. The built-in self-monitoring could malfunction or indicate an error if the ...

  • Page 7

    Page 7 – + 7.4 placement of motion field – – + + inclination -5° to 90° in 5° increments pivot -20° to 20° in 5° increments – – + + + – 7.2 adjusting the motion field size to meet standard requirements 3 ft 6 ft 0 ft 3 ft 6 ft 9 ft 9 ft 0 ft t 3 f 3 ft tt 0 f 0 ft 0 f 0 ft t 0 f 0 ft t 6 f 6 ft t 9 ...

  • Page 8

    Page 8 8.2 motion sensor settings 8 lcd panel location configuration (operator buttons) black button red button 8.1 entering configuration mode function (select with red button) lcd values (select with black button) description factory settings in bold with * field size/sensitivity 1 1 - 5 1 = small...

  • Page 9

    Page 9 8.4 general settings 8.3 safety curtain settings function (select with red button) lcd values (select with black button) description factory settings in bold with * sensitivity 1 2, 3 2 = regular sensitivity* 3 = snow mode teach-in time the amount of time until the sensor recognizes a motionl...

  • Page 10

    Page 10 troubleshooting remedying false tripping 9.1 9 red led (safety) green led (motion) fault remedy off on door reverses while closing 1. Ensure door header coverplate is in place and held . Tightly by screws. 2. Set angle of microwave further away from door (section 7.4). 3. Reduce microwave fi...

  • Page 11: Bircher Reglomat Prime

    Page 11 10 common door operator wiring diagrams 10.1 besam unislide error messages 9.2 red led (safety) green led (motion) lcd fault remedy flashing off 1: self test (ram/rom) 2: watchdog 1. Power down & repower sensor or restart sensor by pressing & holding red button for 1 second. 2. If sensor dis...

  • Page 12

    Page 12 10.3 dorma esa-ii 1 2 3 4 5 6 7 8 9 10 11 12 13 14 - 27v + 15 - radar outside 16 - ground 17 - 27v + 18 - radar inside 19 - ground 20 - 27v + 21 - presence 2 22 - 27v + 23 - monitoring 2 out 24 - ground 25 - 27v + 26 - presence 1 27 - 27v + 28 - monitoring 1 out 29 - ground 30 31 32 33 34 pr...

  • Page 13

    Page 13 10.5 record series 5100 parameter control panel locking input aux. Sw ext. Sw in emerg.Opn/cls input input ext. Sw in emerg.Opn/cls aux. Sw safety beam aux. Sw disabled sidescrn sensr aux. Sw disabled safety beam sidescrn sensr parameter driving cycle drive time delayopen exterior primetec n...

  • Page 14

    10.6 stanley mc 521 o 1 o 2 o 3 o 4 o 5 o 6 o 7 o 8 o 9 o 10 connector tb4: combined motion/safety outputs alternatively black inside and outside primetecs alternatively red inside and outside primetecs 12vac 12vac common white inside primetec green inside primetec inside sensor 12vac 12vac common o...

  • Page 15

    Page 15 10.8 additional door operator wiring diagrams this device complies with part 15 of the fcc rules and with rss-210 of industry canada. Operation is subject to the following two conditions: - this device may not cause harmful interference. - this device must accept any interference received, i...

  • Page 16

    Technical data 12 optional accessories 13 bircher reglomat 870 pratt avenue n schaumburg, il 60193 phone: 847-952-3730 toll-free: 800-252-1272 fax: 847-952-2005 email: sales@bircherreglomat.Com web: www.Bircherreglomat.Com (2 91 85 1/ f) 35 57 24 a 0 3/ 17 manufacturer: bircher reglomat ag, wiesenga...