Bircher Reglomat PrimeTec User manual - page 10
Page 10
Troubleshooting
Remedying False Tripping
9.1
9
Red LED
(Safety)
Green LED
(Motion)
Fault
Remedy
Off
On
Door reverses while closing
1. Ensure door header coverplate is in place and held
.
tightly by screws.
2. Set angle of microwave further away from door (section 7.4).
3. Reduce microwave field size/sensitivity (section 8.2).
Off
On
Opening signal without
apparent external influence
1. Make sure there are no moving objects such as plants, etc in
.....
the vicinity of the sensor.
2. Mount sensor away from fluorescent or HID light sources.
3. Direct microwave module away from other microwave
sensors in the area ( section 7.4).
4. Activate filter (section 8.2).
On
On
Door reverses while closing
1. Ensure door header coverplate is in place and held
.
tightly by screws.
2. Move door manually.
On
On
Safety detection without
apparent external influence
1. Mount sensor away from fluorescent or HID light sources.
2. Avoid puddles of water on the ground.
3. Avoid interference from other IR sensors by using
a different frequency setting (section 8.4).
4. Use reduced sensitivity (snow mode) (section 8.3).
5. Use separate power supply for sensor & door operator.
Make sure it meets minimum sensor voltage requirement
of 12V.
6. Use recommended 6-wire wiring with separate motion &
safety signals (section 4.2).
Off
Off
Door stays open
1. Change output logic of safety or motion output (NO/NC) (section 8).
If a satisfactory solution cannot be achieved after troubleshooting a problem, please call Bircher Reglomat at 800-252-1272
or visit our website at www.bircherreglomat.com.
DO NOT LEAVE ANY PROBLEMS UNRESOLVED! DO NOT SACRIFICE SAFETY FOR ANY REASON!
If using
separate
safety &
motion
outputs, only
red indicator
LED will be
illuminated.
If sensor sees door:
- Set angle of safety
curtain further away
from door panel
(section 6.2).
The built-in self-monitoring
could malfunction or indicate
an error if the safety curtain is
angled too far away from the
door panel.
If sensor does not see door but
problem persists (ie. experien-
cing EM disturbance):
- Reduce sensitivity of the IR safety
curtain (snow mode) (section 8.3).
- Use separate power supply for
sensor & door operator. Ensure
it meets minimum sensor
voltage requirement of 12V.
- Use recommended 6-wire
wiring with separate motion &
safety signals (section 4.2).
1
1
1
If using
separate
safety &
motion
outputs, only
red indicator
LED will be
illuminated.
1