Bircher Reglomat PrimeTec User manual - page 5
A B C D
Initialization
Safety Curtain Adjustment
6
5
The alternate flashing LED’s indicate the initialization (teach-in) of the sensor.
(Duration 10 - 15 sec.) The LED’s will then remain continuously lit for 10 more
seconds. Please see below for LCD screen readouts.
REMOVE all foreign OBJECTS that are not part of the normal
door system environment BEFORE powering on the sensor.
Make sure no people or moving objects are in the door area,
otherwise correct startup will not be possible.
The door system is now operational at this point.
The safety/motion LED’s will only illuminate when a detection occurs.
If using combined outputs (standard), the green LED will illuminate together with
the red LED when a safety detection occurs.
Red LED
(Safety
)
Possible safety curtain width settings
The width of the safety curtain can be adjusted by clicking in the plastic masking cover in front of the sensor lens.
Sensor without masking cover: full pattern size (factory setting)
Field width: approx. 6’6” (2 m) at 7’ (2.1 m) mounting height
Field depth: approx 8” (.2 m) for 2 rows
Adjusting the Safety Curtain Width
6.1
A
B
C
D
Page 5
A B C D
A B C D
A B C D
Insert masking cover in slot
below lens
Click into place
The field size varies depending on which sections of the lens are masked by the click-in covers.
Rule of thumb: field width is approximately equal to
mounting height.
Green LED
(Motion)
Screen during
initialization
Screen after
initialization
Location of slot below lens
Red button
Location of safety curtain
masking covers inside sensor
cover
Safety Curtain Dimensions
Adjusting the safety curtain width using click-in masking covers