Bircher Reglomat PrimeTec User manual - page 8
Page 8
8.2
Motion Sensor Settings
8
LCD panel location
Configuration (Operator Buttons)
Black button
Red button
8.1
Entering Configuration Mode
Function
(Select with
RED button)
LCD
Values
(Select with
BLACK button)
Description
Factory settings in bold with *
Field Size/Sensitivity
1
1 - 5
1 = Smallest field
4 = Standard field*
5 = Largest field
Direction Recognition
2
1, 2
1 = Off (traffic both ways activates
sensor)
2 = Towards sensor only*
Cross Traffic Optimization
(CTO)
4
1, 2
1 = Off*
2 = Masking of cross traffic
(to reduce unwanted openings
from people walking by the door)
Slow Motion Detection
.
(SMD)
5
1, 2
1 = Off*
2 = On (keeps door open after initial
activation for people
hesitating/pausing before
reaching the safety curtain)
Interference Filter
6
1, 2
1 = Filter off*
2 = Filter on
for EM interference, fluorescent
.......
tubes, door movement, etc
(section 9.1)
Output Logic
7
1, 2
1 = NO*
2 = NC
1
Motion Functions
1
1
1
1
1
1
1
1
Start in
automatic
mode
Shortly press
the red
&
black buttons
simultaneously
to enter confi-
guration mode.
Once in configura-
tion mode, the circ-
led number in the
LCD display will
start to blink. Press
the red button until
you reach the desi-
red function block.
Once in the desired fun-
ction block, press the
red button to browse
through the options.
Use the black button to
change
the
value.
Selections are saved
immediately.
1
Press the black button
to select the function
block shown in the dis-
play.
2
= Motion Functions
1 2
=
General
Functions
Once all changes
are
complete,
press the red &
black
buttons
simultaneously
twice to return to
automatic mode.
= Safety Functions
End in
automatic
mode
Sensor returns to automatic mode in
60 seconds if no action is taken.