7.4
Placement of Motion Field
–
–
+
+
Inclination
-5° to 90° in 5° increments
Pivot
-20° to 20° in 5° increments
–
–
+
+
+
–
7.2
Adjusting the Motion Field Size to Meet Standard Requirements
3 ft
6 ft
0 ft
3 ft
6 ft
9 ft
9 ft
0 ft
t
3 f
3 ft
tt
0 f
0 ft
0 f
0 ft
t
0 f
0 ft
t
6 f
6 ft
t
9 f
9 ft
6 f
t
9 f
9 ft
t
6 f
6 ft
t
3 f
3 ft
t
0 f
0 ft
Minimum Field Size: W x D = 6” x 30” (0.16 x 0.8 m )
Maximum Field Size: W x D = 6’ 6” x 13’ (2 x 4 m)
Measured at 30° angle
Minimum Field Size: W x D = 20” x 10” (0.5 x 0.25 m)
Maximum Field Size: W x D = 13’ x 6’ 6” (4 x 2 m)
Measured at 30° angle
3 ft
6 ft
0 ft
9 ft
12 ft
0 ft
3 ft
t
0 f
0 ft
t
3 f
3 ftt
3 f
3 ft
t
6 f
6 ft
t
9 f
9 ft
12 ft
12 f
12 ft
3 ft
3 f
3 ft
t
0 f
0 ft
7’
(2
.1
m
)
7’
(2
.1
m
)
7.3
Motion Field Dimensions
In order to meet ANSI standard 156.10, the sensor’s
motion field pattern must cover the ANSI-specified field
dimensions (designated by x’s in the drawing).
Please refer to the current published ANSI standard for
details.
Rule of thumb: The width:depth ratio of the motion field is approximately 2:1 (standard field) or 1:2 (narrow field)
Field size changes with mounting height.
Standard Field
Narrow Field
Factory setting: 20° (5 clicks up from end)
Factory setting: 0°