Bircher Reglomat PrimeTec User manual - page 9
Page 9
8.4
General Settings
8.3
Safety Curtain Settings
Function
(Select with
RED button)
LCD
Values
(Select with
BLACK button)
Description
Factory settings in bold with *
Sensitivity
1
2, 3
2 = Regular sensitivity*
3 = Snow mode
Teach-In Time
The amount of time until
the sensor recognizes a
motionless person/object in
the safety curtain field as
part of the background
2
1 - 5
1 = 10 seconds
2 = 30 seconds*
3 = 60 seconds
4 = 180 seconds
5 = 15 minutes
Output Logic
3
1, 2
1 = NO*
2 = NC
Safety Functions
2
2
2
2
Please note: some settings may not meet all applicaple standards (eg. ANSI 156.10). Please see page 2 for more details.
Ensure (e.g. by walk testing) that installation is in compliance with all applicable standards (e.g. ANSI 156.10)
after completion of installation.
General Settings
Function
(Select with
RED button)
LCD
Values
(Select with
BLACK button)
Description
Factory settings in bold with *
Combined/separate outputs
2
1, 2
1 = 4-wire configuration*
(combined outputs for motion
& safety)
2 = 6-wire configuration
(separate outputs for motion
& safety)
Shortcut: Press & hold black
button for 8 seconds to separate
motion & safety outputs
Frequency of safety curtain
Can be changed to prevent
cross-talk from two sensors
on the same door (e.g. very
wide door)
3
1, 2
1 = Frequency 1*
2 = Frequency 2
1
2
1
2
LCD after using
shortcut:
8.5
Restarting the Sensor
To restart the sensor, press & hold the red button for 1 second. This is equivalent to recycling power
(powering down the sensor and up again).
8.6
Factory Reset
To reset the sensor to factory defaults settings, press & hold both red & black buttons simultaneously for 8 seconds.
2
1