Bircher Reglomat PrimeTec User manual - page 3
Insert the female plug on the gray
cable into the male receptacle on the
sensor. Ensure the plug is fully inser-
ted.
Wiring the Sensor
3.3
Template
Middle of door opening
Position the removable self-adhesive mounting template on
the door header frame in the middle of the opening (see illus-
trations) Ensure template is level on the door header frame
and the bottom of the template is aligned with the bottom of
the door header frame (-1” / + 3” tolerance).
Drill hole for cable in marked location using 1/4” drill bit for
cable only or 1/2” for cable + connector.
Using an electric screwdriver, insert self-tapping screws in
marked location. Torque rating is 3.7 ft-lb (5 Nm).
Remove the mounting template.
Attach sensor to screws and tighten to hold the sensor
firmly on the door header frame.
Positioning & Attaching the Sensor
3.5
Double sliding door
ouble sliding door
Double sliding door
Single sliding door
Single sliding door
Single sliding door
Shown above is the 4-wire retrofit
wiring scenario using the deta -
chable screw terminal. Insert the
proper wires into terminal (based
on the wiring diagram on page 4)
and tighten the screws with a 1/8”
flathead screwdriver.
New installation using gray cable
with plug
Page 3
Retrofit installation using
detachable screw terminal
MT-PT 0611
Align with center of door header
PrimeTec Self-Adhesive Mounting Template
Align with bottom of door header
Screw
Screw
Dia. 1/2” (12 mm) for cable exit
= Cable feed space
Route the cable in the cable channels so it is flush against the back of the sensor.
Several options are shown- select the best option for your installation.
Routing the Cable (for retrofit installations with existing cable hole)
3.4
Important note: for both options, slide the cable into the cable bushing to hold it firmly in place.
Use of the cable bushing is important to prevent water from seeping into the sensor.
M
ax
im
um
m
ou
nt
in
g
he
ig
ht
=
1
3’
(4
m
)
The cable will only fit into the re-
ceptacle if the grooves are lined up
properly. Do not force the connec-
tor into the receptacle or
damage could result.
Proper insertion of the cable
connector into receptacle
-1” / + 3” tolerance
1.
2.
3.
4.
5.