Bircher Reglomat PrimeTec User manual - page 4
Sensor must be programmed for this wiring configuration.
Press and hold the black value button for 8 seconds to separate motion & safety outputs.
For more details, please see section 8.
This option may only be used with the included gray cable.
Electrical Connections
4
4-Wire Connection: Standard Option (Combined motion & safety outputs)
4.1
6-Wire Connection: Recommended Option (Enhanced performace through separate motion & safety outputs)
4.2
8-Wire Connection: Best Option (Additional safety through monitoring)
4.3
Page 4
New installation using gray cable with plug
Retrofit installation using detachable screw terminal
Monitoring function is self-configurating and will be active as soon as unit is powered on if the following wiring is used.
May not be available for all door operators.
Power
11.5 - 36 VDC/
10 - 28 VAC
Black
Red
White
Green
Blue
Brown
Motion
COM
NO (NC)
Safety
Power
11.5 - 36 VDC/
10 - 28 VAC
Black
Red
White
Green
Motion/
Safety
COM
NO
Power
11.5 - 36 VDC/
10 - 28 VAC
Black
Red
White
Green
Blue
Brown
Motion
COM
NO (NC)
Safety
COM
NO (NC)
Power
11.5 - 36 VDC/
10 - 28 VAC
Motion/
Safety
COM
NO
Orange
Yellow
Monitoring
Cable
Cable
Cable
COM
NO (NC)
Sensor must be programmed for this wiring configuration.
Press and hold the black value button for 8 seconds to separate motion & safety outputs.
For more details, please see section 8.
This option may only be used with the included gray cable.
Check for correct polarity
Check for correct polarity
Check for correct polarity
+
+
+